A sensitive assay of amoxicillin in mouse serum and broncho-alveolar lavage fluid by liquid-liquid extraction and reversed-phase HPLC

被引:29
作者
Du, XL [1 ]
Li, CH [1 ]
Sun, HK [1 ]
Nightingale, CH [1 ]
Nicolau, DP [1 ]
机构
[1] Hartford Hosp, Ctr Anti Infect Res & Dev, Hartford, CT 06102 USA
关键词
amoxicillin; HPLC;
D O I
10.1016/j.jpba.2005.04.021
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive and simple high-performance liquid chromatography (HPLC) method was developed and validated for the analysis of amoxicillin in mouse serum and broncho-alveolar lavage (BAL) fluid. One hundred microlitres of sample were needed for the assay. Sample processing was carried out with liquid-liquid extraction. Cefadroxil was used as an internal standard. The chromatographic separation was achieved on a C-18 reversed-phase column with a mobile phase consisting of phosphate buffer, 1-octanesulphonic acid sodium salt and acetonitrile. The detection was conducted at 2 10 nm. The ranges of the standard curves were 0.2-20 and 0.05-5 mu g/ml for serum and BAL samples, respectively. The recoveries of amoxicillin from serum and normal saline were 87 and 88%, respectively. The coefficients of variation were 1.78-6.13% for intra-day and 0.82-6.42% for inter-day analyses. The accuracy was within 100 +/- 6%. This method was successfully applied to analyze amoxicillin in mouse serum and BAL samples from a pharmacokinetic study. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:648 / 652
页数:5
相关论文
共 16 条
[1]   Determination of amoxycillin in human plasma by direct injection and coupled-column high-performance liquid chromatography [J].
Cass, QB ;
Gomes, RF ;
Calafatti, SA ;
Pedrazolli, J .
JOURNAL OF CHROMATOGRAPHY A, 2003, 987 (1-2) :235-241
[2]   SIMPLE ANALYSIS OF AMOXICILLIN IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH INTERNAL STANDARDIZATION AND ULTRAVIOLET DETECTION [J].
CHARLES, B ;
CHULAVATNATOL, S .
BIOMEDICAL CHROMATOGRAPHY, 1993, 7 (04) :204-207
[3]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF AMOXICILLIN IN URINE USING SOLID-PHASE, ION-PAIR EXTRACTION AND ULTRAVIOLET DETECTION [J].
CHULAVATNATOL, S ;
CHARLES, BG .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 615 (01) :91-96
[4]  
DEPIRES ALR, 2003, J PHARM PHARM SCI, V6, P223
[5]   Antimicrobial susceptibility of community-acquired lower respiratory tract bacterial pathogens isolated in the UK during the 1995-1996 cold season [J].
Felmingham, D ;
Robbins, MJ ;
Tesfaslasie, Y ;
Harding, I ;
Shrimpton, S ;
Grüneberg, RN .
JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 1998, 41 (03) :411-415
[6]   Evolution of amoxicillin/clavulanate in the treatment of adults with acute bacterial rhinosinusitis and community-acquired pneumonia in response to antimicrobial-resistance patterns [J].
File, TM ;
Benninger, MS ;
Jacobs, MR .
CLINICS IN LABORATORY MEDICINE, 2004, 24 (02) :531-+
[7]   PENETRATION OF AMOXICILLIN-CLAVULANIC ACID INTO BRONCHIAL-MUCOSA WITH DIFFERENT DOSING REGIMENS [J].
GOULD, IM ;
HARVEY, G ;
GOLDER, D ;
REID, TMS ;
WATT, SJ ;
FRIEND, JAR ;
LEGGE, JS ;
DOUGLAS, JG .
THORAX, 1994, 49 (10) :999-1001
[8]   REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF AMPHOTERIC BETA-LACTAM ANTIBIOTICS - EFFECTS OF COLUMNS, ION-PAIRING REAGENTS AND MOBILE PHASE PH ON THEIR RETENTION TIMES [J].
HUANG, HS ;
WU, JR ;
CHEN, ML .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 564 (01) :195-203
[9]   Determination of amoxicillin in human serum and plasma by high-performance liquid chromatography and on-line postcolumn derivatisation [J].
Mascher, HJ ;
Kikuta, C .
JOURNAL OF CHROMATOGRAPHY A, 1998, 812 (1-2) :221-226
[10]   Simultaneous quantification of amoxycillin and metronidazole in plasma using high-performance liquid chromatography with photodiode array detection [J].
Menelaou, A ;
Somogyi, AA ;
Barclay, ML ;
Bochner, F .
JOURNAL OF CHROMATOGRAPHY B, 1999, 731 (02) :261-266