Repeatability of Measuring Corneal Subbasal Nerve Fiber Length in Individuals With Type 2 Diabetes

被引:73
作者
Efron, Nathan [1 ,2 ]
Edwards, Katie [1 ,2 ]
Roper, Nicola [3 ]
Pritchard, Nicola [1 ,2 ]
Sampson, Geoff P. [1 ,2 ]
Shahidi, Ayda M. [1 ,2 ]
Vagenas, Dimitrios [1 ,2 ]
Russell, Anthony [4 ]
Graham, Jim [5 ]
Dabbah, Mohammad A. [5 ]
Malik, Rayaz A. [6 ]
机构
[1] Queensland Univ Technol, Inst Hlth & Biomed Innovat, Kelvin Grove, Qld 4059, Australia
[2] Queensland Univ Technol, Sch Optometry, Kelvin Grove, Qld 4059, Australia
[3] Univ Manchester, Fac Life Sci, Manchester, Lancs, England
[4] Princess Alexandra Hosp, Brisbane, Qld 4102, Australia
[5] Univ Manchester, Sch Canc & Enabling Sci, Manchester, Lancs, England
[6] Univ Manchester, Div Cardiovasc Med, Core Technol Facil, Manchester, Lancs, England
来源
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE | 2010年 / 36卷 / 05期
基金
英国医学研究理事会;
关键词
Repeatability; Corneal nerves; Diabetes; Neuropathy; VIVO CONFOCAL MICROSCOPY; IN-VIVO; REGENERATION; NEUROPATHY; IMAGES; DAMAGE;
D O I
10.1097/ICL.0b013e3181eea915
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To analyze the repeatability of measuring nerve fiber length (NFL) from images of the human corneal subbasal nerve plexus using semiautomated software. Methods: Images were captured from the corneas of 50 subjects with type 2 diabetes mellitus who showed varying severity of neuropathy, using the Heidelberg Retina Tomograph 3 with Rostock Corneal Module. Semiautomated nerve analysis software was independently used by two observers to determine NFL from images of the subbasal nerve plexus. This procedure was undertaken on two occasions, 3 days apart. Results: The intraclass correlation coefficient values were 0.95 (95% confidence intervals: 0.92-0.97) for individual subjects and 0.95 (95% confidence intervals: 0.74-1.00) for observer. Bland-Altman plots of the NFL values indicated a reduced spread of data with lower NFL values. The overall spread of data was less for (a) the observer who was more experienced at analyzing nerve fiber images and (b) the second measurement occasion. Conclusions: Semiautomated measurement of NFL in the subbasal nerve fiber layer is highly repeatable. Repeatability can be enhanced by using more experienced observers. It may be possible to markedly improve repeatability when measuring this anatomic structure using fully automated image analysis software.
引用
收藏
页码:245 / 248
页数:4
相关论文
共 17 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]  
DABBAH MA, 2010, P 13 INT C MED IM CO
[3]   Subbasal nerve regeneration after penetrating keratoplasty [J].
Darwish, Taym ;
Brahma, Arun ;
Efron, Nathan ;
O'Donnell, Clare .
CORNEA, 2007, 26 (08) :935-940
[4]   Subbasal nerve fiber regeneration after LASIK and LASEK assessed by noncontact esthesiometry and in vivo confoccal microscopy: Prospective study [J].
Darwish, Taym ;
Brahma, Arun ;
O'Donnell, Clare ;
Efron, Nathan .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (09) :1515-1521
[5]   New perspectives on keratoconus as revealed by corneal confocal microscopy [J].
Efron, Nathan ;
Hollingsworth, Joanna G. .
CLINICAL AND EXPERIMENTAL OPTOMETRY, 2008, 91 (01) :34-55
[6]   Contact lens-induced changes in the anterior eye as observed in vivo with the confocal microscope [J].
Efron, Nathan .
PROGRESS IN RETINAL AND EYE RESEARCH, 2007, 26 (04) :398-436
[7]   Assessing the sub-basal nerve plexus of the living healthy human cornea by in vivo confocal microscopy [J].
Grupcheva, CN ;
Wong, T ;
Riley, AF ;
McGhee, CNJ .
CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2002, 30 (03) :187-190
[8]  
*I STAT MATH, 2009, R STAT PACK VERS 2 1
[9]   Corneal confocal microscopy: a non-invasive surrogate of nerve fibre damage and repair in diabetic patients [J].
Malik, RA ;
Kallinikos, P ;
Abbott, CA ;
van Schie, CHM ;
Morgan, P ;
Efron, N ;
Boulton, AJM .
DIABETOLOGIA, 2003, 46 (05) :683-688
[10]   Design and validation of a tool for neurite tracing and analysis in fluorescence microscopy images [J].
Meijering, E ;
Jacob, M ;
Sarria, JCF ;
Steiner, P ;
Hirling, H ;
Unser, M .
CYTOMETRY PART A, 2004, 58A (02) :167-176