Association of air pollution with increased incidence of ventricular tachyarrhythmias recorded by implanted cardioverter defibrillators

被引:206
作者
Dockery, DW
Luttmann-Gibson, H
Rich, DQ
Link, MS
Mittleman, MA
Gold, DR
Koutrakis, P
Schwartz, JD
Verrier, RL
机构
[1] Harvard Univ, Sch Publ Hlth, Exposure Epidemiol & Risk Program, Dept Environm Hlth,Landmark Ctr, Boston, MA 02215 USA
[2] Brigham & Womens Hosp, Channing Lab, Boston, MA USA
[3] Harvard Univ, Sch Med, Boston, MA USA
[4] Tufts Univ, New England Med Ctr, Boston, MA 02111 USA
[5] Harvard Univ, Sch Publ Hlth, Dept Epidemiol, Boston, MA 02115 USA
[6] Beth Israel Deaconess Med Ctr, Boston, MA 02215 USA
[7] Harvard Univ, Sch Med, Boston, MA USA
关键词
D O I
10.1289/ehp.7767
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Epidemiologic studies have demonstrated a consistent link between sudden cardiac deaths and particulate air pollution. We used implanted cardioverter defibrillator (ICD) records of ventricular tachyarrhythmias to assess the role of air pollution as a trigger of these potentially life-threatening events. The study cohort consisted of 203 cardiac patients with ICD devices in the Boston metropolitan area who were followed for an average of 3.1 years between 1995 and 2002. Fine particle mass and gaseous air pollution plus temperature and relative humidity were measured on almost all days, and black carbon, sulfate, and particle number on a subset of days. Date, time, and intracardiac electrograms of ICD-detected arrhythmias were downloaded at the patients' regular follow-up visits (about every 3 months). Ventricular tachyarrhythmias were identified by electrophysiologist review. Risk of ventricular arrhythmias associated with air pollution was estimated with logistic regression, adjusting for season, temperature, relative humidity, day of the week, patient, and a recent prior arrhythmia. We found increased risks of ventricular arrhythmias associated with 2-day mean exposure for all air pollutants considered, although these associations were not statistically significant. We found statistically significant associations between air-pollution and ventricular arrhythmias for episodes within 3 days of a previous arrhythmia. The associations of ventricular tachyarrhythmias with fine particle mass, carbon monoxide, nitrogen dioxide, and black carbon suggest a link with motor vehicle pollutants.
引用
收藏
页码:670 / 674
页数:5
相关论文
共 30 条
[1]   Air pollution and cardiovascular disease - A statement for healthcare professionals from the expert panel on population and prevention science of the American Heart Association [J].
Brook, RD ;
Franklin, B ;
Cascio, W ;
Hong, YL ;
Howard, G ;
Lipsett, M ;
Luepker, R ;
Mittleman, M ;
Samet, J ;
Smith, SC ;
Tager, I .
CIRCULATION, 2004, 109 (21) :2655-2671
[2]   Inhaled concentrated ambient particles are associated with hematologic and bronchoalveolar lavage changes in canines [J].
Clarke, RW ;
Coull, B ;
Reinisch, U ;
Catalano, P ;
Killingsworth, CR ;
Koutrakis, P ;
Kavouras, I ;
Murthy, GGK ;
Lawrence, J ;
Lovett, E ;
Wolfson, JM ;
Verrier, RL ;
Godleski, JJ .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2000, 108 (12) :1179-1187
[3]   Particulate matter and heart rate variability among elderly retirees: the Baltimore 1998 PM study [J].
Creason, J ;
Neas, L ;
Walsh, D ;
Williams, R ;
Sheldon, L ;
Liao, DP ;
Shy, C .
JOURNAL OF EXPOSURE ANALYSIS AND ENVIRONMENTAL EPIDEMIOLOGY, 2001, 11 (02) :116-122
[4]   Air pollution and myocardial infarction in Rome - A case-crossover analysis [J].
D'Ippoliti, D ;
Forastiere, F ;
Ancona, C ;
Agabiti, N ;
Fusco, D ;
Michelozzi, P ;
Perucci, CA .
EPIDEMIOLOGY, 2003, 14 (05) :528-535
[5]   AMBULATORY SUDDEN CARDIAC DEATH - MECHANISMS OF PRODUCTION OF FATAL ARRHYTHMIA ON THE BASIS OF DATA FROM 157 CASES [J].
DELUNA, AB ;
COUMEL, P ;
LECLERCQ, JF .
AMERICAN HEART JOURNAL, 1989, 117 (01) :151-159
[6]   AN APPROACH TO THE ANALYSIS OF REPEATED MEASUREMENTS [J].
DIGGLE, PJ .
BIOMETRICS, 1988, 44 (04) :959-971
[7]  
DOCKERY DW, 124 HEI
[8]  
GODLESKI JJ, 2000, 91 HEI
[9]   Ambient pollution and heart rate variability [J].
Gold, DR ;
Litonjua, A ;
Schwartz, J ;
Lovett, E ;
Larson, A ;
Nearing, B ;
Allen, G ;
Verrier, M ;
Cherry, R ;
Verrier, R .
CIRCULATION, 2000, 101 (11) :1267-1273
[10]   ACC/AHA Guidelines for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices: Executive summary - A report of the American College of Cardiology American Heart Association Task Force on Practice Guidelines (Committee on Pacemaker Implantation) [J].
Gregoratos, G ;
Cheitlin, MD ;
Conill, A ;
Epstein, AE ;
Fellows, C ;
Ferguson, TB ;
Freedman, RA ;
Hlatky, MA ;
Naccarelli, GV ;
Saksena, S ;
Schlant, RC ;
Silka, MJ .
CIRCULATION, 1998, 97 (13) :1325-1335