Comparison of methods for harmonic wavelet analysis of heart rate variability

被引:6
作者
Bates, RA [1 ]
Hilton, MF
Godfrey, KR
Chappell, MJ
机构
[1] Univ Warwick, Dept Engn, Coventry CV4 7AL, W Midlands, England
[2] Birmingham Heartlands Hosp, Dept Resp Physiol, Birmingham B9 5SS, W Midlands, England
关键词
biomedical engineering; harmonic wavelet analysis;
D O I
10.1049/ip-smt:19982321
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Two different methods for the spectral analysis of heart rate variability data are compared: the discrete Fourier transform and the nonequispaced Fourier transform. The methods are used to analyse test signals that are constructed to mimic R-R interval data, with graded levels of noise, generated using the integral pulse frequency modulation model. It is found that the nonequispaced Fourier transform is the better method for determining the frequency coefficients of the test signals as the noise level is increased. Both methods are compared when they are used as the first step in a time-frequency analysis of the test signals using the discrete harmonic wavelet transform, and a quantitative comparison is made on a set of randomly generated test signals (this shows that the nonequispaced Fourier transform is the better method). A further study shows the ability of the discrete harmonic wavelet transform to detect frequencies close to the boundary between wavelet levels. Since each harmonic wavelet represents a distinct frequency band, careful choice of sampling frequency means that such wavelets can be used to identify spectral bands associated with physiological causes. A. clinical example, using the nonequispaced Fourier transform, shows how the discrete harmonic wavelet transform could be developed for use in detecting brief alterations in autonomic tone.
引用
收藏
页码:291 / 300
页数:10
相关论文
共 15 条
[1]   POWER SPECTRUM ANALYSIS OF HEART-RATE FLUCTUATION - A QUANTITATIVE PROBE OF BEAT-TO-BEAT CARDIOVASCULAR CONTROL [J].
AKSELROD, S ;
GORDON, D ;
UBEL, FA ;
SHANNON, DC ;
BARGER, AC ;
COHEN, RJ .
SCIENCE, 1981, 213 (4504) :220-222
[2]  
Camm AJ, 1996, EUR HEART J, V17, P354
[3]   AN ALGORITHM FOR MACHINE CALCULATION OF COMPLEX FOURIER SERIES [J].
COOLEY, JW ;
TUKEY, JW .
MATHEMATICS OF COMPUTATION, 1965, 19 (90) :297-&
[4]   FAST FOURIER-TRANSFORMS FOR NONEQUISPACED DATA [J].
DUTT, A ;
ROKHLIN, V .
SIAM JOURNAL ON SCIENTIFIC COMPUTING, 1993, 14 (06) :1368-1393
[5]  
EWING DJ, 1991, BRIT HEART J, V65, P239
[6]   SLEEP APNEA SYNDROMES [J].
GUILLEMINAULT, C ;
TILKIAN, A ;
DEMENT, WC .
ANNUAL REVIEW OF MEDICINE, 1976, 27 :465-484
[7]   ACCURACY OF ASSESSMENT OF CARDIAC VAGAL TONE BY HEART-RATE-VARIABILITY IN NORMAL SUBJECTS [J].
HAYANO, J ;
SAKAKIBARA, Y ;
YAMADA, A ;
YAMADA, M ;
MUKAI, S ;
FUJINAMI, T ;
YOKOYAMA, K ;
WATANABE, Y ;
TAKATA, K .
AMERICAN JOURNAL OF CARDIOLOGY, 1991, 67 (02) :199-204
[8]   ASSOCIATION OF SLEEP-APNEA WITH MYOCARDIAL-INFARCTION IN MEN [J].
HUNG, J ;
WHITFORD, EG ;
PARSONS, RW ;
HILLMAN, DR .
LANCET, 1990, 336 (8710) :261-264
[9]   SIGNIFICANCE OF LONG-TERM COMPONENTS OF HEART-RATE-VARIABILITY FOR THE FURTHER PROGNOSIS AFTER ACUTE MYOCARDIAL-INFARCTION [J].
MALIK, M ;
CAMM, AJ .
CARDIOVASCULAR RESEARCH, 1990, 24 (10) :793-803
[10]   POWER SPECTRAL-ANALYSIS OF CARDIOVASCULAR VARIABILITY IN PATIENTS AT RISK FOR SUDDEN CARDIAC DEATH [J].
MALLIANI, A ;
LOMBARDI, F ;
PAGANI, M ;
CERUTTI, S .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1994, 5 (03) :274-286