Measurement of the internal diameter and depth of the anterior chamber: IOLMaster versus anterior chamber optical coherence tomographer

被引:86
作者
Baikoff, G [1 ]
Jodai, HJ [1 ]
Bourgeon, G [1 ]
机构
[1] Clin Monticelli, F-13008 Marseille, France
关键词
D O I
10.1016/j.jcrs.2005.02.030
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To study the internal diameter of the anterior chamber (AC), which remains a relatively subjective procedure dominated by the white-to-white technique, evaluated with a compass or using anterior segment photographs. In vivo dimensions of the AC were studied with an optical coherence tomographer (AC OCT) prototype. SETTING: Clinique Monticelli, Marseilles, France. METHODS: The dimensions in 107 normal eyes that had never had surgery were studied with the IOLMaster and AC OCT. RESULTS: The mean anterior chamber depth was 3.53 mm +/- 0.35 (SD) with the IOLMaster (Carl Zeiss, Medictec) and 3.64 +/- 0.33 mm with the AC OCT (Carl Zeiss, Medictec). The mean horizontal diameter of the AC was 12.12 +/- 0.44 mm with the IOLMaster and 12.20 +/- 0.44 mm with the AC OCT. With the AC OCT, the anterior chamber's horizontal and vertical diameter could be evaluated; in 74% of the observed eyes, the vertical diameter was larger by at least 100 mu m than the horizontal diameter. DISCUSSION: The AC OCT has better reproducibility than the IOLMaster for evaluating the depth or internal diameter of the anterior chamber. This study showed that in 74% of cases, the AC was an oval with a larger vertical axis, which provides evidence of the value of the OCT preoperative examinations for phakic intraocular lens implantation.
引用
收藏
页码:1722 / 1728
页数:7
相关论文
共 28 条
[1]   Biometric study of acute-angle-closure glaucoma using Orbscan and echography [J].
Allouch, C ;
Touzeau, O ;
Borderie, V ;
Fogel, S ;
Zito, E ;
Laroche, L .
JOURNAL FRANCAIS D OPHTALMOLOGIE, 2004, 27 (03) :239-248
[2]  
[Anonymous], 1996, OPTICAL COHERENCE TO
[3]   Correction of presbyopia with refractive multifocal phakic intraocular lenses [J].
Baïkoff, G ;
Matach, G ;
Fontaine, A ;
Ferraz, C ;
Spera, C .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (07) :1454-1460
[4]   Contact between 3 phakic intraocular lens models and the crystalline lens: An anterior chamber optical coherence tomography study [J].
Baikoff, G ;
Wei, LJ ;
Ferraz, C .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (09) :2007-2012
[5]   Static and dynamic analysis of the anterior segment with optical coherence tomography [J].
Baikoff, G ;
Lutun, E ;
Ferraz, C .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (09) :1843-1850
[6]  
BAIKOFF G, IN PRESS J CATARACAT
[7]  
BOKER T, 1995, OPHTHALMIC RES, V27, P104
[8]  
Drexler W, 1997, INVEST OPHTH VIS SCI, V38, P1304
[9]  
Fercher A. F., 1986, Proceedings of the SPIE - The International Society for Optical Engineering, V658, P48, DOI 10.1117/12.938523
[10]  
Fercher A F, 1996, J Biomed Opt, V1, P157, DOI 10.1117/12.231361