Selection of hydrothermal pre-treatment conditions of waste sludge destruction using multicriteria decision-making

被引:27
作者
Khalil, WAS
Shanableh, A
Rigby, P
Kokot, S
机构
[1] Queensland Univ Technol, Sch Civil Engn, Brisbane, Qld, Australia
[2] Univ Sharjah, Dept Civil Engn, Sharjah, U Arab Emirates
[3] Queensland Univ Technol, Sch Phys & Chem Sci, Inorgan Mat Res Program, Brisbane, Qld, Australia
关键词
sludge waste; hydrothermal; chemometrics; PROMETHEE and GAIA; hydrogen peroxide; COD;
D O I
10.1016/j.jenvman.2004.11.007
中图分类号
X [环境科学、安全科学];
学科分类号
08 [工学]; 0830 [环境科学与工程];
摘要
The effectiveness of hydrothermal treatment for the destruction of the organic content of sludge waste was investigated. The sludge sampled in this study contained approximately 2% solids. The experimental program consisted of hydrothermal treatment experiments conducted in a batch reactor at temperatures between 100 and 250 degrees C, with the addition of an oxidant (hydrogen peroxide) in the range of 0-150% with reference to TCOD, and reaction times of up to 60 min. The results suggested that the availability of oxidant, reaction temperature and reaction time were the determining factors for COD removal. A significant fraction of the COD remaining after treatment consisted of the dissolved COD. The results confirmed that hydrothermal treatment proceeds through hydrolysis resulting in the production of dissolved organic products followed by COD removal through oxidation. Two MCDM chemometrics methods, PROMETHEE and GAIA, were applied to process the large data matrix so as to facilitate the selection of the most suitable hydrothermal conditions for sludge destruction. Two possible scenarios were produced from this analysis-one depended on the use of high temperatures and no oxidant, while the second offered a choice of compromise solutions at lower temperatures but with the use of at least some oxidant. Thus, for the final choice of operating conditions, the decision maker needs local knowledge of the costs and available infrastructure. In principle, such information could be added as further criteria to the data matrix and new rankings obtained. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:53 / 64
页数:12
相关论文
共 34 条
[1]
[Anonymous], 1995, Standard methods for examination of water and waste water, V19th
[2]
Biomass gasification in supercritical water [J].
Antal, MJ ;
Allen, SG ;
Schulman, D ;
Xu, XD ;
Divilio, RJ .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2000, 39 (11) :4040-4053
[3]
AYOKO G, 2003, HLTH BUILD C SING
[4]
AYOKO G, 2002, 6 INT AER C TAIP TAI, P597
[5]
BRANS JP, 1991, PROMCALC VERSION 3 1
[6]
WET OXIDATION OF ACTIVE-CARBON [J].
CHAREST, F ;
CHORNET, E .
CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1976, 54 (03) :190-196
[7]
Supercritical water oxidation of sludges contaminated with toxic organic chemicals [J].
Crain, N ;
Shanableh, A ;
Gloyna, E .
WATER SCIENCE AND TECHNOLOGY, 2000, 42 (7-8) :363-368
[8]
OXIDATION OF PROPIONIC-ACID SOLUTIONS [J].
DAY, DC ;
HUDGINS, RR ;
SILVESTO.PL .
CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1973, 51 (06) :733-740
[9]
Negotiation support systems: A multi-criteria and multi-agent approach [J].
Espinasse, B ;
Picolet, G ;
Chouraqui, E .
EUROPEAN JOURNAL OF OPERATIONAL RESEARCH, 1997, 103 (02) :389-409
[10]
HURWITZ E, 1965, WATER SEWAGE WORKS, V112, P298