Prompt-gamma activation analysis using the k0 approach

被引:71
作者
Molnar, GL
Revay, Z
Paul, RL
Lindstrom, RM
机构
[1] Inst Isotopes, Dept Nucl Res, H-1525 Budapest, Hungary
[2] NIST, Div Analyt Chem, Gaithersburg, MD 20899 USA
关键词
D O I
10.1007/BF02389741
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Applying the k(0) standardization method to prompt-gamma activation analysis (PGAA) offers similar benefits as in instrumental neutron activation analysis. It has been demonstrated that under constant flux conditions k(0)-factors obtained by normalizing to a titanium comparator, measured separately, yield consistent analytical sensitivity ratios. The ratio method has been generalized by using stoichiometric compounds for the determination of k(0)-factors. Since chlorine forms compounds with essentially every element and it also serves as a detector efficiency standard, k(0) values have been determined relative to chlorine as an internal standard for several analytically important elements in two reactor facilities: the thermal guided beam at the ERR in Budapest and the cold-neutron beams at the NBSR at NIST.
引用
收藏
页码:21 / 26
页数:6
相关论文
共 17 条
[1]  
Alfassi Z. B., 1995, PROMPT GAMMA NEUTRON
[2]   FACILITY FOR NONDESTRUCTIVE ANALYSIS FOR MAJOR AND TRACE-ELEMENTS USING NEUTRON-CAPTURE GAMMA-RAY SPECTROMETRY [J].
ANDERSON, DL ;
FAILEY, MP ;
ZOLLER, WH ;
WALTERS, WB ;
GORDON, GE ;
LINDSTROM, RM .
JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1981, 63 (01) :97-119
[3]   Gamma intensity standard from thermal neutron capture in Cl-35 [J].
Coceva, C ;
Brusegan, A ;
vanderVorst, C .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 378 (03) :511-514
[4]   KO-MEASUREMENTS AND RELATED NUCLEAR-DATA COMPILATION FOR (N,GAMMA) REACTOR NEUTRON-ACTIVATION ANALYSIS [J].
DECORTE, F ;
SIMONITS, A ;
DEWISPELAERE, A ;
ELEK, A .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1989, 133 (01) :3-41
[5]   Introducing HYPERMET-PC for automatic analysis of complex gamma-ray spectra [J].
Fazekas, B ;
Molnar, G ;
Belgya, T ;
Dabolczi, L ;
Simonits, A .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1997, 215 (02) :271-277
[6]  
FAZEKAS B, MARC 4 P
[7]  
Lindstrom R. M., 1995, PROMPT GAMMA NEUTRON, P93
[8]  
LINDSTROM RM, 1992, P INT K0 US WORKSH R, P125
[9]  
Lone M.A., 1981, Atomic Data and Nuclear Data Tables, V26, P511
[10]   USE OF SPHERICAL TARGETS TO MINIMIZE EFFECTS OF NEUTRON-SCATTERING BY HYDROGEN IN NEUTRON-CAPTURE PROMPT GAMMA-RAY ACTIVATION-ANALYSIS [J].
MACKEY, EA ;
GORDON, GE ;
LINDSTROM, RM ;
ANDERSON, DL .
ANALYTICAL CHEMISTRY, 1992, 64 (20) :2366-2371