Sonography detection threshold for knee effusion

被引:34
作者
Delaunoy, I
Feipel, V
Appelboom, T
Hauzeur, JP
机构
[1] Univ Brussels, Erasme Hosp, B-1070 Brussels, Belgium
[2] Univ Brussels, Lab Anat, Brussels, Belgium
关键词
hydrarthrosis; joint effusion; joint fluid; knee; synovitis; ultrasonography;
D O I
10.1007/s10067-003-0759-5
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
The aim of this study was to determine the threshold for detecting knee effusion by ultrasound (US). Five knee specimens from embalmed cadavers were studied. Intra-articular injection of saline, blood and synovial fluid was performed under ultrasound control and methylene blue dye instillation. The smallest amount of fluid detectable by US in the knee was 7.4 ml for synovial fluid, 10.1 and 10.4 ml for saline solution and 9.7 for blood. The threshold for detecting knee joint effusion by US in cadaver specimens was 10 ml for saline and blood and 7 ml for synovial fluid.
引用
收藏
页码:391 / 392
页数:2
相关论文
共 3 条
[1]
Hauzeur JP, 1999, J RHEUMATOL, V26, P2681
[2]
Detection of ankle effusions: Comparison study in cadavers using radiography, sonography, and MR imaging [J].
Jacobson, JA ;
Andresen, R ;
Jaovisidha, S ;
De Maeseneer, M ;
Foldes, K ;
Trudell, DR ;
Resnick, D .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (05) :1231-1238
[3]
IMPROVED DIAGNOSTIC-IMAGING IN JOINT DISEASES [J].
SELTZER, SE ;
WEISSMAN, BN ;
FINBERG, HJ ;
MARKISZ, JA .
SEMINARS IN ARTHRITIS AND RHEUMATISM, 1982, 11 (03) :315-330