Measurement of blood flow through the retinal circulation of the cat during normoxia and hypoxemia using fluorescent microspheres

被引:36
作者
Ahmed, J
Pulfer, MK
Linsenmeier, RA
机构
[1] Northwestern Univ, Dept Biomed Engn, Evanston, IL 60208 USA
[2] Northwestern Univ, Dept Neurobiol & Physiol, Evanston, IL 60208 USA
[3] Northwestern Univ, Integrated Sci Program, Evanston, IL 60208 USA
关键词
retina; retinal circulation; blood flow; fluorescent microspheres; cat; hypoxemia;
D O I
10.1006/mvre.2001.2321
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
The most successful method for measuring absolute blood flow rate through the retinal circulation has been the use of radioactive microspheres. The purpose of this study was to develop a microsphere method that did not have the drawbacks associated with radioactivity and to use this method to make measurements of retinal blood flow in the cat. Blood flow measurements were made by injecting 15-mum-diameter polystyrene microspheres into the left ventricle of anesthetized, artificially ventilated cats. These microspheres were labeled with one of three fluorescent dyes. Retinal blood flow measurements were made by determining the number of spheres that were embedded in the retina and comparing them to the number found in a reference sample. Spheres in the retina were counted by making retinal whole mounts and taking retinal images with a CCD camera mounted on an epifluorescence microscope equipped with filter sets appropriate for imaging the dyes used to label the spheres. Blood flow measurements made under normal conditions showed a mean retinal blood flow of 19.8 +/- 12.4 ml/min 100 g tissue (mean +/- SD; n=15 cats). Since the retinal circulation perfuses only the inner half of the retina, the effective flow rate in that region is about twice this value. RBF increased during hypoxemia. (PaO2<42 mm Hg) to 336% of the normoxic value on average. Analysis of sphere deposition patterns showed that the central retina had a higher blood flow than the peripheral retina, although this difference was significant only during hypoxemia. We conclude that even with a relatively small number of spheres deposited in the retina, the technique can reveal important properties of the retinal circulation. (C) 2001 Academic Press.
引用
收藏
页码:143 / 153
页数:11
相关论文
共 29 条
[1]   OCULAR AND OPTIC-NERVE BLOOD-FLOW AT NORMAL AND INCREASED INTRAOCULAR PRESSURES IN MONKEYS (MACACA-IRUS) - STUDY WITH RADIOACTIVELY LABELED MICROSPHERES INCLUDING FLOW DETERMINATIONS IN BRAIN AND SOME SOME OTHER TISSUES [J].
ALM, A ;
BILL, A .
EXPERIMENTAL EYE RESEARCH, 1973, 15 (01) :15-29
[3]  
Bill A., 1984, HDB PHYSL 2, P1001
[4]  
BRAUN RD, 1995, INVEST OPHTH VIS SCI, V36, P542
[5]   SOME SOURCES OF ERROR IN MEASURING REGIONAL BLOOD FLOW WITH RADIOACTIVE MICROSPHERES [J].
BUCKBERG, GD ;
LUCK, JC ;
PAYNE, DB ;
HOFFMAN, JIE ;
ARCHIE, JP ;
FIXLER, DE .
JOURNAL OF APPLIED PHYSIOLOGY, 1971, 31 (04) :598-&
[6]   EFFECTS OF INDOMETHACIN ON CEREBRAL BLOOD-FLOW DURING HYPERCAPNIA IN CATS [J].
BUSIJA, DW ;
HEISTAD, DD .
AMERICAN JOURNAL OF PHYSIOLOGY, 1983, 244 (04) :H519-H524
[7]   EFFECTS OF D-ISOMERS AND L-ISOMERS OF TIMOLOL ON RETINAL AND CHOROIDAL BLOOD-FLOW IN OCULAR HYPERTENSIVE RABBIT EYES [J].
CHIOU, GCY ;
CHEN, YJ .
JOURNAL OF OCULAR PHARMACOLOGY, 1992, 8 (03) :183-190
[8]  
DUKER JS, 1996, DUANES FDN CLIN OPHT, V2, pCH5
[9]  
EPERON G, 1975, INVEST OPHTH VISUAL, V14, P342
[10]   CONTROL OF RETINAL CIRCULATION AT ALTITUDE [J].
FRAYSER, R ;
GRAY, GW ;
HOUSTON, CS .
JOURNAL OF APPLIED PHYSIOLOGY, 1974, 37 (03) :302-304