A dynamic simulator to evaluate distal radio-ulnar joint kinematics

被引:16
作者
Haugstvedt, JR [1 ]
Berglund, LJ [1 ]
Neale, PG [1 ]
Berger, RA [1 ]
机构
[1] Mayo Clin & Mayo Fdn, Dept Orthoped Surg, Biomech Lab, Rochester, MN 55905 USA
关键词
D O I
10.1016/S0021-9290(00)00198-6
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
In order to perform cadaveric biomechanical studies of the human forearm and distal radio-ulnar joint, a dynamic simulator has been constructed. The device is based upon a Plexiglas frame, to which the ulna is secured in a vertical orientation and the humerus in a horizontal orientation. The hand is secured in a sliding bar linkage to a stepper-motor that is used to rotate the forearm. The tendons to be loaded are connected to pneumatic actuators that provide agonist and antagonist muscle loading resulting in torque along the forearm axis. The muscle loading profiles and magnitudes are programmable as a function of the pronation-supination position and direction. A magnetic tracking system is used to collect three-dimensional kinematics data of up to four segments, in conjunction with the muscle tendon loads, forearm torque and other prescribed experimental measures. All functions are under PC control using custom software written with LabVIEW(TM) (National Instruments, Austin, TX). For the DRUJ tearing, the validity of the tendon loading protocol to produce physiologic torque/rotation patterns was verified using in vivo data. The relationship of individual muscle forces to forearm torque was determined by a cadaveric study. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:335 / 339
页数:5
相关论文
共 15 条
[1]
DISTAL RADIOULNAR LIGAMENT MOTION DURING SUPINATION AND PRONATION [J].
ACOSTA, R ;
HNAT, W ;
SCHEKER, LR .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1993, 18B (04) :502-505
[2]
PARTIAL EXCISION OF THE TRIANGULAR FIBROCARTILAGE COMPLEX ARTICULAR DISK - A BIOMECHANICAL STUDY [J].
ADAMS, BD .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1993, 18A (02) :334-340
[3]
Amis A. A., 1979, Engineering in Medicine, V8, P41, DOI 10.1243/EMED_JOUR_1979_008_010_02
[4]
BASMAJIAN JV, 1985, MUSCLES ALIVE THEIR, P280
[5]
Brand P. W., 1993, CLIN MECH HAND
[6]
RELATIVE TENSION AND POTENTIAL EXCURSION OF MUSCLES IN THE FOREARM AND HAND [J].
BRAND, PW ;
THOMPSON, DE .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1981, 6 (03) :209-219
[7]
Ekenstam F, 1985, SCAND J PLAST RECONS, V19, P17, DOI [10.3109/02844318509052861, DOI 10.3109/02844318509052861]
[8]
Simulation of elbow and forearm motion in vitro using a load controlled testing apparatus [J].
Johnson, JA ;
Rath, DA ;
Dunning, CE ;
Roth, SE ;
King, GJW .
JOURNAL OF BIOMECHANICS, 2000, 33 (05) :635-639
[9]
KIHARA H, 1994, P 61 ANN M AM AC ORT, P447
[10]
KINEMATICS OF THE DISTAL RADIOULNAR JOINT [J].
KING, GJ ;
MCMURTRY, RY ;
RUBENSTEIN, JD ;
GERTZBEIN, SD .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1986, 11A (06) :798-804