Platelet storage in PAS-2 or autologous plasma: impact on functional parameters

被引:16
作者
Bunescu, A
Hild, M
Lundahl, J
Egberg, N [1 ]
机构
[1] Karolinska Hosp, Dept Clin Chem, S-17176 Stockholm, Sweden
[2] Nova Med St Gorans Hosp, Dept Clin Chem, Stockholm, Sweden
[3] Karolinska Hosp, Dept Clin Immunol & Transfus Med, S-17176 Stockholm, Sweden
关键词
flow cytometry; PAS-2; platelet storage lesion;
D O I
10.1046/j.1365-3148.2001.00293.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Currently, several platelet additive solutions for long-term platelet storage have been introduced. The aim of this study was to compare the deterioration of functional status of platelets stored for up to 5 days in autologous plasma (AP) only, with platelet stored in PAS-2, a salt solution containing acetate, citrate and sodium chloride. Change in platelet adhesion, aggregation and activation was measured by flow cytometric technique. In addition, beta -Thromboglobulin (beta -TG), lactate and glucose were determined. After 5 days of storage, the expression of P-Selectin was significantly higher, the production of lactate and the consumption of glucose were significantly lower, in platelets stored in PAS-2 than in autologous plasma. No significant differences were detected on day 5 between the two groups with regard to fibrinogen, von Willebrand factor binding capacity, or to beta -TG release. It can be concluded that neither storage medium was consistently better for the parameters tested. However, it must be emphasized that platelets stored in autologous plasma exhibited less lesion, in terms of P-Selectin expression compared with platelets stored in PAS-2.
引用
收藏
页码:105 / 110
页数:6
相关论文
共 26 条
[1]   EVALUATION OF PLATELET CONCENTRATES PREPARED FROM BUFFY COATS AND STORED IN A GLUCOSE-FREE CRYSTALLOID MEDIUM [J].
BERTOLINI, F ;
REBULLA, P ;
RICCARDI, D ;
CORTELLARO, M ;
RANZI, ML ;
SIRCHIA, G .
TRANSFUSION, 1989, 29 (07) :605-609
[2]   EVALUATION OF PLATELET-FUNCTION BY FLOW CYTOMETRIC MEASUREMENT OF LIGAND-BINDING [J].
BUNESCU, A ;
LUNDAHL, J ;
SODERSTROM, T ;
LINDAHL, T ;
LARSSON, A ;
EGBERG, N .
PLATELETS, 1995, 6 (06) :340-345
[3]   Platelets stored in a new-generation container - Differences between plasma and platelet additive solution II [J].
de Wildt-Eggen, J ;
Schrijver, JG ;
Smid, WM ;
Joie, M ;
Bollinne, V ;
Bins, M .
VOX SANGUINIS, 1998, 75 (03) :218-223
[4]   Reactions and platelet increments after transfusion of platelet concentrates in plasma or an additive solution: a prospective, randomized study [J].
de Wildt-Eggen, J ;
Nauta, S ;
Schrijver, JG ;
Kooy, MV ;
Bins, M ;
van Prooijen, HC .
TRANSFUSION, 2000, 40 (04) :398-403
[5]   PLATELET CONCENTRATES IN AN ADDITIVE SOLUTION PREPARED FROM POOLED BUFFY COATS .1. INVITRO STUDIES [J].
ERIKSSON, L ;
HOGMAN, CF .
VOX SANGUINIS, 1990, 59 (03) :140-145
[6]  
FRATANTONI JC, 1984, J LAB CLIN MED, V103, P620
[7]   BUFFY-COAT-DERIVED PLATELET CONCENTRATES PREPARED FROM HALF-STRENGTH CITRATE CPD AND CPD WHOLE-BLOOD UNITS - COMPARISON BETWEEN 3 ADDITIVE SOLUTIONS - IN-VITRO STUDIES [J].
GULLIKSSON, H ;
ERIKSSON, L ;
HOGMAN, CF ;
PAYRAT, JM .
VOX SANGUINIS, 1995, 68 (03) :152-159
[8]   ROUTINE QUALITY ASSURANCE REQUIREMENTS FOR APHERESED PLATELETS [J].
HOGMAN, CF .
TRANSFUSION SCIENCE, 1993, 14 (01) :85-88
[9]   NEW TRENDS IN THE PREPARATION AND STORAGE OF PLATELETS [J].
HOGMAN, CF .
TRANSFUSION, 1992, 32 (01) :3-6
[10]   IMPROVED INVIVO AND INVITRO VIABILITY OF PLATELET CONCENTRATES STORED FOR 7 DAYS IN A PLATELET ADDITIVE SOLUTION [J].
HOLME, S ;
HEATON, WA ;
COURTRIGHT, M .
BRITISH JOURNAL OF HAEMATOLOGY, 1987, 66 (02) :233-238