Characterization of electrode fouling and surface regeneration for a platinum electrode on an electrophoresis microchip

被引:109
作者
Manica, DP
Mitsumori, Y
Ewing, AG [1 ]
机构
[1] Penn State Univ, Dept Chem, Davey Lab 152, University Pk, PA 16801 USA
[2] Tohoku Univ, Dept Biomol Engn, Sendai, Miyagi 9808579, Japan
关键词
D O I
10.1021/ac034235f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method of electrochemically cleaning noble metal electrodes is presented and characterized for electrophoresis microchips with electrochemical detection. First, the loss of sensitivity due to electrode fouling by serotonin is characterized as a function of injection number and analyte concentration. Signal attenuation is observed to be greater at high concentrations (100 muM) and negligible at very low concentrations (similar to1 muM). Next, an electrochemical treatment procedure is optimized to yield sensitive and reproducible amperometric detection of the highly adsorptive compounds, serotonin and histamine. Thus, the performance of the electrode is reproducibly regenerated following as much as a similar to99% reduction in surface activity. Utilizing the optimized three-level waveform, derived from that used for pulsed amperometric detection, detection limits as low as 78 nM and 17 muM have been obtained for serotonin and histamine, respectively. In the case of serotonin, this represents the lowest detection limit for a neurotransmitter by microchip electrophoresis with amperometric detection and the first report of amperometric detection of histamine detection at an unmodified platinum electrode. Repeated use of the electrode and application of electrochemical treatment did not appear to measurably affect the noise, longevity, metal adhesion, or physical appearance of the electrode.
引用
收藏
页码:4572 / 4577
页数:6
相关论文
共 51 条
[1]  
ADAMS RN, 1969, ELECTROCHEMISTRY SOL, P189
[2]   SIMULTANEOUS DETERMINATIONS OF HISTAMINE AND N-TAU-METHYLHISTAMINE BY HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY-CHEMILUMINESCENCE COUPLED WITH IMMOBILIZED DIAMINE OXIDASE [J].
ALAM, MK ;
SASAKI, M ;
WATANABE, T ;
MAEYAMA, K .
ANALYTICAL BIOCHEMISTRY, 1995, 229 (01) :26-34
[3]   Micro total analysis systems. 2. Analytical standard operations and applications [J].
Auroux, PA ;
Iossifidis, D ;
Reyes, DR ;
Manz, A .
ANALYTICAL CHEMISTRY, 2002, 74 (12) :2637-2652
[4]   Fully integrated on-chip electrochemical detection for capillary electrophoresis in a microfabricated device [J].
Baldwin, RP ;
Roussel, TJ ;
Crain, MM ;
Bathlagunda, V ;
Jackson, DJ ;
Gullapalli, J ;
Conklin, JA ;
Pai, R ;
Naber, JF ;
Walsh, KM ;
Keynton, RS .
ANALYTICAL CHEMISTRY, 2002, 74 (15) :3690-3697
[5]  
Baldwin RP, 2000, ELECTROPHORESIS, V21, P4017, DOI 10.1002/1522-2683(200012)21:18<4017::AID-ELPS4017>3.3.CO
[6]  
2-X
[7]   SEPARATION OF HUMAN BREAST-CANCER CELLS FROM BLOOD BY DIFFERENTIAL DIELECTRIC AFFINITY [J].
BECKER, FF ;
WANG, XB ;
HUANG, Y ;
PETHIG, R ;
VYKOUKAL, J ;
GASCOYNE, PRC .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1995, 92 (03) :860-864
[8]   Sample filtration, concentration, and separation integrated on microfluidic devices [J].
Broyles, BS ;
Jacobson, SC ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 2003, 75 (11) :2761-2767
[9]  
Bruin GJM, 2000, ELECTROPHORESIS, V21, P3931, DOI 10.1002/1522-2683(200012)21:18<3931::AID-ELPS3931>3.0.CO
[10]  
2-M