Diffusion tensor imaging of the normal prostate at 3 Tesla

被引:46
作者
Gurses, Bengi [1 ,4 ]
Kabakci, Neslihan [1 ]
Kovanlikaya, Arzu [1 ]
Firat, Zeynep [1 ]
Bayram, Ali [1 ]
Ulug, Aziz Muefit [2 ,3 ]
Kovanlikaya, Ilhami [1 ]
机构
[1] Yeditepe Univ Hosp, Dept Radiol, TR-34752 Istanbul, Turkey
[2] Yeditepe Univ, Sch Engn, Dept Biomed Engn, TR-34755 Istanbul, Turkey
[3] Cornell Univ, Weill Med Coll, Dept Radiol, New York, NY 10021 USA
[4] Yeditepe Univ Hastanesi, TR-34752 Istanbul, Turkey
关键词
prostate; MRI; diffusion;
D O I
10.1007/s00330-007-0795-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to assess the feasibility of diffusion tensor imaging (DTI) of the prostate and to determine normative fractional anisotropy (FA) and apparent diffusion coefficient (ADC) values of healthy prostate with a 3-Tesla magnetic resonance imaging (MRI) system. Thirty volunteers with a mean age of 28 (25-35) years were scanned with a 3-Tesla MRI (Intera Achieva; Philips, The Netherlands) system using a six-channel phased array coil. Initially, T2-weighted turbo spin-echo (TSE) axial images of the prostate were obtained. In two subjects, a millimetric hypointense signal change was detected in the peripheral zones on T2-weighted TSE images. These two subjects were excluded from the study. DTI with single-shot echo-planar imaging (ssEPI) was performed in the remaining 28 subjects. ADC and FA values were measured using the manufacturer supplied software by positioning 9-pixel ROIs on each zone. Differences between parameters of the central and peripheral zones were assessed. Mean ADC value of the central (1.220 +/- 0.271 x 10(-3) mm(2)/s) was found to be significantly lower when compared with the peripheral gland (1.610 +/- 0.347 x 10(-3) mm(2)/s) (P < 0.01). Mean FA of the central gland was significantly higher (0.26), compared with the peripheral gland (0.16) (P < 0.01). This study shows the feasibility of prostate DTI with a 3-Tesla MR system and the normative FA and ADC values of peripheral and central zones of the normal prostate. The results are compatible with the microstructural organization of the gland.
引用
收藏
页码:716 / 721
页数:6
相关论文
共 23 条
[1]   Imaging of prostate cancer [J].
Akin, Oguz ;
Hricak, Hedvig .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2007, 45 (01) :207-+
[2]  
CHEN AP, 2003, P 11 ANN M ISMRM TOR
[3]   Diffusion-weighted MRI in the evaluation of renal lesions: preliminary results [J].
Cova, M ;
Squillaci, E ;
Stacul, F ;
Manenti, G ;
Gava, S ;
Simonetti, G ;
Pozzi-Mucelli, R .
BRITISH JOURNAL OF RADIOLOGY, 2004, 77 (922) :851-857
[4]   Magnetic resonance imaging in prostate cancer: the value of apparent diffusion coefficients for identifying malignant nodules [J].
DeSouza, N. M. ;
Reinsberg, S. A. ;
Scurr, E. D. ;
Brewster, J. M. ;
Payne, G. S. .
BRITISH JOURNAL OF RADIOLOGY, 2007, 80 (950) :90-95
[5]   Diffusion imaging of the prostate at 3.0 tesla [J].
Gibbs, P ;
Pickles, MD ;
Turnbull, LW .
INVESTIGATIVE RADIOLOGY, 2006, 41 (02) :185-188
[6]  
Haker SJ, 2005, P 13 ANN M ISMRM MIA
[7]   RETRACTED: New horizons in genitourinary oncologic imaging (Retracted article. See vol. 40, pg. 2065, 2015) [J].
Hricak, H .
ABDOMINAL IMAGING, 2006, 31 (02) :182-187
[8]   Prostatic MR imaging - Accuracy in differentiating cancer from other prostatic disorders [J].
Ikonen, S ;
Kivisaari, L ;
Tervahartiala, P ;
Vehmas, T ;
Taari, K ;
Rannikko, S .
ACTA RADIOLOGICA, 2001, 42 (04) :348-354
[9]   Endorectal magnetic resonance imaging of prostatic cancer:: comparison between fat-suppressed T2-weighted fast spin echo and three-dimensional dual-echo, steady-state sequences [J].
Ikonen, S ;
Kärkkäinen, P ;
Kivisaari, L ;
Salo, JO ;
Taari, K ;
Vehmas, T ;
Tervahartiala, P ;
Rannikko, S .
EUROPEAN RADIOLOGY, 2001, 11 (02) :236-241
[10]   In vivo measurement of the apparent diffusion coefficient in normal and malignant prostatic tissues using echo-planar imaging [J].
Issa, B .