Assessing mechanical allodynia in the rat paw with a new electronic algometer

被引:92
作者
Möller, KA
Johansson, B
Berge, OG
机构
[1] Astra Pain Control AB, Discovery Unit, In Vivo Pharmacol, Novum, S-14157 Huddinge, Sweden
[2] Somed Sales AB, S-24294 Horby, Sweden
关键词
allodynia; neuropathy; pain; electronic pressure algometer; von Frey filaments; withdrawal thresholds; rat;
D O I
10.1016/S0165-0270(98)00083-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Von Frey filaments used for testing mechanical thresholds are mechanically unstable and their use is difficult to standardize. We have therefore constructed a hand-held electronic pressure algometer. The pressure algometer is connected to a computerized data collection system, allowing on-line display of the applied force as well as the application rate. Data stored on the computer can be replayed and further analyzed. Using this apparatus, we have measured the pressure-induced withdrawal thresholds in rats with surgically induced neuropathy. The probe, with a circular tip of 1.0 mm diameter, was applied manually with a pressure increasing by approximately 0.05 N/s. Presurgical thresholds were normally distributed with a mean of 0.415 N, showing no significant difference between paws. During 2 weeks after surgery, the thresholds of the operated side were significantly reduced (range, 0.209-0.318 N), while the thresholds of the non-operated side remained at higher values (range, 0.432-0.491 N). Thresholds of control rats without surgery were in the 0.380-0.520 N range, with no significant difference between paws. In an additional experiment it was shown that interobserver reliability was high, both between withdrawal threshold values obtained and between rates of application used. In conclusion, the electronic algometer allows standardization of testing, detailed documentation of each experiment and provides an objective and accurate method for measuring the reactions of test animals to mechanical stimuli. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:41 / 47
页数:7
相关论文
共 14 条
[1]   THE EFFECT OF CHANGES IN TEMPERATURE AND HUMIDITY ON THE ACCURACY OF VON FREY HAIRS [J].
ANDREWS, K .
JOURNAL OF NEUROSCIENCE METHODS, 1993, 50 (01) :91-93
[2]   RELATION OF PAIN SENSORY THRESHOLD TO FORM OF MECHANICAL STIMULATOR [J].
BISHOP, GH .
JOURNAL OF NEUROPHYSIOLOGY, 1949, 12 (01) :51-57
[3]   Neomycin and gadolinium applied to an L5 spinal nerve lesion prevent mechanical allodynia-like behaviour in rats [J].
Blenk, KH ;
Habler, HJ ;
Janig, W .
PAIN, 1997, 70 (2-3) :155-165
[4]   QUANTITATIVE ASSESSMENT OF TACTILE ALLODYNIA IN THE RAT PAW [J].
CHAPLAN, SR ;
BACH, FW ;
POGREL, JW ;
CHUNG, JM ;
YAKSH, TL .
JOURNAL OF NEUROSCIENCE METHODS, 1994, 53 (01) :55-63
[5]   EFFICIENT ANALYSIS OF EXPERIMENTAL-OBSERVATIONS [J].
DIXON, WJ .
ANNUAL REVIEW OF PHARMACOLOGY AND TOXICOLOGY, 1980, 20 :441-462
[6]   STIMULUS FEATURES RELEVANT TO THE PERCEPTION OF SHARPNESS AND MECHANICALLY EVOKED CUTANEOUS PAIN [J].
GREENSPAN, JD ;
MCGILLIS, SLB .
SOMATOSENSORY AND MOTOR RESEARCH, 1991, 8 (02) :137-147
[7]  
GREENSPAN JD, 1990, PAIN S, V5, pS313
[8]  
HANDWERKER HO, 1987, CONTRIBUTIONS PAIN R, P70
[9]   PRESSURE-PAIN THRESHOLD IN HUMAN TEMPORAL REGION - EVALUATION OF A NEW PRESSURE ALGOMETER [J].
JENSEN, K ;
ANDERSEN, HO ;
OLESEN, J ;
LINDBLOM, U .
PAIN, 1986, 25 (03) :313-323
[10]  
KIM SH, 1992, PAIN, V50, P355, DOI 10.1016/0304-3959(92)90041-9