A computer-based laparoscopic skills assessment device differentiates experienced from novice laparoscopic surgeons

被引:65
作者
McNatt, SS [1 ]
Smith, CD [1 ]
机构
[1] Emory Univ, Sch Med, Dept Surg, Emory USSC Endosurg Unit, Atlanta, GA 30322 USA
来源
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES | 2001年 / 15卷 / 10期
关键词
laparoscopy; skills assessment; surgical simulation; surgical training; education; surgical education;
D O I
10.1007/s004640080022
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: The acquisition of laparoscopic skills is difficult to assess. Previously, through the use of a computer-based skills assessment device (SAD), we have shown that assessments of the time needed to perform a task and graded observations of task performance overestimate the speed at which laparoscopic skills can be acquired. The aim of this study was to test the ability of a laparoscopic SAD to differentiate novices from experienced laparoscopic surgeons and thereby further validate its use in surgical education. Methods: Using a laparoscopic simulator platform intergrated with task simulation and data collection software (MIST VR), we tested both experienced and novice laparoscopists. Each group performed three tasks with a minimum of seven repetitions. The tasks consisted of target acquisition, target traversal, and target manipulation with diathermy. Within each task, time (T), errors (E), and economy of movement for each hand (EML, EMR) were assessed. Results were reported as mean SEM, and comparisons were made using an independent samples t-test. Results: For the target acquisition task, the expert group performed the task faster than the novice group (5.5 +/- 0.24 vs 7.6 +/- 0.40 see, p < 0.05); the experts also made fewer errors (0.5 +/- 0.10 vs 0.8 +/- 0.11 errors, p < 0.05), and achieved both a better EML (1.8 +/- 0.6 vs 2.3 +/- 0.9, p < 0.05) and a better EMR (2.0 +/- 0.1 vs 2.9 +/- 0.21, p < 0.05). In the target traversal task, the experts made fewer errors than the novices (2.2 +/- 0.25 vs 4.6 +/- 0.38 errors, p < 0.05). For the manipulation and diathermy tasks, the expert group completed the task faster (30.8 +/- 1.5 vs 39 +/- 1.5 see, p < 0.05), made fewer errors (5.3 +/- 0.59 vs 8.1 +/- 0.63 errors, p < 0.05), and had a better EML (6.0 +/- 0.37 vs 7.2 +/- 0.45, p < 0.05) and EMR (4.3 +/- 0.23 vs 5.8 +/- 0.36, p < 0.05) than the novices. Conclusion: A laparoscopic skills assessment device can discern levels of laparoscopic manipulative skill. This type of device can be used in surgical training to make objective assessments of the acquisition of laparoscopic skills.
引用
收藏
页码:1085 / 1089
页数:5
相关论文
共 6 条
[1]
Development of a model for training and evaluation of laparoscopic skills [J].
Derossis, AM ;
Fried, GM ;
Abrahamowicz, M ;
Sigman, HH ;
Barkun, JS ;
Meakins, JL .
AMERICAN JOURNAL OF SURGERY, 1998, 175 (06) :482-487
[2]
Downes M, 1998, ST HEAL T, V50, P316
[3]
Objective evaluation of a laparoscopic surgical skill program [J].
Gagner, M .
ARCHIVES OF SURGERY, 1998, 133 (08) :911-912
[4]
Objective evaluation of a laparoscopic surgical skill program for residents and senior surgeons [J].
Rosser, JC ;
Rosser, LE ;
Savalgi, RS .
ARCHIVES OF SURGERY, 1998, 133 (06) :657-661
[5]
SMITH CD, 1998, SURG ENDOSC, V12, P492
[6]
Wilson MS, 1997, ANN ROY COLL SURG, V79, P403