Markov Reliability Modeling for Induction Motor Drives Under Field-Oriented Control

被引:91
作者
Bazzi, Ali M. [1 ]
Dominguez-Garcia, Alejandro [1 ]
Krein, Philip T. [1 ]
机构
[1] Univ Illinois, Grainger Ctr Elect Machinery & Electromech, Dept Elect & Comp Engn, Urbana, IL 61801 USA
关键词
Fault impact assessment; induction motor drive; Markov's reliability model; FAULT-DETECTION; AC DRIVES; PERFORMANCE; METHODOLOGY; DESIGN; SPEED;
D O I
10.1109/TPEL.2011.2168543
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
080906 [电磁信息功能材料与结构]; 082806 [农业信息与电气工程];
摘要
This paper presents a Markov reliability model of induction motor drives operating under field-oriented control. The model includes faults in the power electronics, machine, speed encoder, and current sensors. The procedure can be extended for more detail, to other machines and to other drive topologies. To develop the model, faults are first identified, and then, a simulation model of the setup is developed and experimentally verified. Faults are injected into the model in sequential levels and the system performance is assessed after each fault. Fault coverage-the probability that the system survives given a fault has occurred-is studied. A complete Markov reliability model is developed to assess the mean time to failure of the system and other reliability factors. This analysis is shown to be simple and useful for assessing the reliability of motor drives and is expected to help in designing fault-tolerance mechanisms for specific drives, where reliability can be evaluated after every design.
引用
收藏
页码:534 / 546
页数:13
相关论文
共 43 条
[1]
Abolhassani Mehdi T., 2009, 2009 IEEE International Electric Machines and Drives Conference (IEMDC), P1146, DOI 10.1109/IEMDC.2009.5075348
[2]
Alshandoli AF, 2007, 2007 INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING, P27
[3]
[Anonymous], 1984, 500 ANSIIEEE
[4]
[Anonymous], 1995, MILHDBK217F US DEP D
[5]
[Anonymous], 2006, P 37 IEEE POW EL SPE
[6]
[Anonymous], 2003, 5062650001 SPECTR DI
[7]
A Method for Impact Assessment of Faults on the Performance of Field-Oriented Control Drives: A First Step to Reliability Modeling [J].
Bazzi, Ali M. ;
Dominguez-Garcia, Alejandro ;
Krein, Philip T. .
2010 TWENTY-FIFTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC), 2010, :256-263
[8]
Bennett JW, 2004, IEEE POWER ELECTRON, P4371
[9]
Simple model for post-fault motor behaviour for reliability power quality assessment of industrial power systems [J].
Bollen, MHJ ;
Dirix, PME .
IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 1996, 143 (01) :56-60
[10]
Bolognani Silverio, 2006, IECON 2006. 32nd Annual Conference on IEEE Industrial Electronics (IEEE Cat. No. 06CH37763), P2307, DOI 10.1109/IECON.2006.347388