Does intensity windowing improve the detection of simulated calcifications in dense mammograms?

被引:19
作者
Pisano, ED
Chandramouli, J
Hemminger, BM
DeLuca, M
Glueck, D
Johnston, RE
Muller, K
Braeuning, MP
Pizer, S
机构
[1] UNIV N CAROLINA, SCH MED, DEPT COMP SCI, CHAPEL HILL, NC USA
[2] UNIV N CAROLINA, SCH MED, DEPT BIOMED ENGN, CHAPEL HILL, NC USA
[3] UNIV N CAROLINA, DEPT BIOSTAT, SCH MED, CHAPEL HILL, NC USA
[4] UNIV N CAROLINA, SCH PUBL HLTH, DEPT RADIOL, CHAPEL HILL, NC USA
[5] UNIV N CAROLINA, SCH PUBL HLTH, DEPT COMP SCI, CHAPEL HILL, NC USA
[6] UNIV N CAROLINA, SCH PUBL HLTH, DEPT BIOMED ENGN, CHAPEL HILL, NC USA
[7] UNIV N CAROLINA, SCH MED, DEPT BIOSTAT, CHAPEL HILL, NC USA
[8] COLL ARTS & SCI, CHAPEL HILL, NC USA
关键词
mammography; image processing; intensity windowing; observer studies; calcifications; computers; radiology;
D O I
10.1007/BF03168559
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study attempts to determine whether intensity windowing (IW) improves detection of simulated calcifications in dense mammograms. Clusters of five simulated calcifications were embedded in dense mammograms digitized at 50-mu m pixels, 12 bits deep. Film images with no windowing applied were compared with film images with nine different window widths and levels applied. A simulated cluster was embedded in a realistic background of dense breast tissue, with the position of the cluster varied. The key variables involved in each trial included the position of the cluster, contrast level of the cluster, and the IW settings applied to the image. Combining the ten IW conditions, four contrast levels and four quadrant positions gave 160 combinations. The trials were constructed by pairing 160 combinations of key variables with 160 backgrounds. The entire experiment consisted of 800 trials. Twenty student observers were asked to detect the quadrant of the image in which the mass was located. There was a statistically significant improvement in detection performance for clusters of calcifications when the window width was set at 1024 with a level of 3328, and when the window width was set at 1024 with a level of 3456. The selected IW settings should be tested in the clinic with digital mammograms to determine whether calcification detection performance can be improved. Copyright (C) 1997 by W.B. Saunders Company.
引用
收藏
页码:79 / 84
页数:6
相关论文
共 17 条
[1]   IMAGE FEATURE ANALYSIS AND COMPUTER-AIDED DIAGNOSIS IN DIGITAL RADIOGRAPHY .1. AUTOMATED DETECTION OF MICROCALCIFICATIONS IN MAMMOGRAPHY [J].
CHAN, HP ;
DOI, K ;
GALHOTRA, S ;
VYBORNY, CJ ;
MACMAHON, H ;
JOKICH, PM .
MEDICAL PHYSICS, 1987, 14 (04) :538-548
[2]   DIGITAL MAMMOGRAPHY - ROC STUDIES OF THE EFFECTS OF PIXEL SIZE AND UNSHARP-MASK FILTERING ON THE DETECTION OF SUBTLE MICROCALCIFICATIONS [J].
CHAN, HP ;
VYBORNY, CJ ;
MACMAHON, H ;
METZ, CE ;
DOI, K ;
SICKLES, EA .
INVESTIGATIVE RADIOLOGY, 1987, 22 (07) :581-589
[3]  
HALE DA, 1994, J SURG ONCOL, V55, P42
[4]  
HOMER MJ, 1991, MAMMOGRAPHIC INTERPR, P4
[5]   LESION CONSPICUITY, STRUCTURED NOISE, AND FILM READER ERROR [J].
KUNDEL, HL ;
REVESZ, G .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1976, 126 (06) :1233-1238
[6]  
MACMILLAN NA, 1991, DETECTION THEORY USE, P135
[7]   ENHANCED IMAGE MAMMOGRAPHY [J].
MCSWEENEY, MB ;
SPRAWLS, P ;
EGAN, RL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1983, 140 (01) :9-14
[8]  
PISANO ED, 1995, RAD SOC N AM M CHIC
[9]  
Pizer S. M., 1985, PICTORIAL INFORMATIO, P211
[10]  
Puff D T, 1994, J Digit Imaging, V7, P161