Normal and pathologic tissue reactions to soft tissue gel fillers

被引:110
作者
Christensen, Lise [1 ]
机构
[1] Bispebjerg Hosp, Dept Pathol, Copenhagen, Denmark
关键词
D O I
10.1111/j.1524-4725.2007.33357.x
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 [皮肤病与性病学];
摘要
BACKGROUND All gels act as foreign bodies. Host response ranges from a few macrophages to an intense foreign-body reaction with fibrosis, depending on gel type. For polymer gels the filling effect stems from their volume. For combination gels it stems from the intended host foreign-body reaction to the microparticles. OBJECTIVE This review explains how host tissue reacts with different gel types and how adverse reactions differ depending on gel type. METHODS AND MATERIALS This study is based on observations during the past 6 1/2 years from experimental/clinical studies and biopsies from adverse reactions. RESULTS Hydrophilic polymer gels constantly exchange water with their host tissue with minimal fibrosis. Degradable gels are encircled and degraded by macrophages; polyacrylamide gel is traversed by macrophages, replaced by fibrous, vessel-bearing strands. All other gels provoke a foreign-body reaction with ensuing fibrosis. Adverse reactions include bacterial infection for the hydrophilic gels and a fibrous granuloma for all other gel types. It is hypothesized that bacteria are maintained within a biofilm (a film comprising bacteria, their nutrients, and their waste products) giving rise to a low-grade infection. CONCLUSIONS Infectious nodules must be treated with antibiotics. Granulomas must be treated with a combination of both steroids and antibiotics or excision.
引用
收藏
页码:S168 / S175
页数:8
相关论文
共 44 条
[1]
Effects of continuous water flow on the swelling properties of polyelectrolyte hydrogels [J].
Bai, G ;
Suzuki, A .
EUROPEAN PHYSICAL JOURNAL E, 2004, 14 (02) :107-113
[2]
SONOGRAPHIC DEMONSTRATION OF MIGRATING SILICONE [J].
BARLOW, RE ;
TORRES, WE ;
SONES, PJ ;
SOMEREN, A .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1980, 135 (01) :170-171
[3]
The value of a new filler material in corrective and cosmetic surgery: DermaLive and DermaDeep [J].
Bergeret-Galley, C ;
Latouche, X ;
Illouz, YG .
AESTHETIC PLASTIC SURGERY, 2001, 25 (04) :249-255
[4]
HYDROGEL PATCHES FOR TRANSDERMAL DRUG DELIVERY - INVIVO WATER EXCHANGE AND SKIN COMPATIBILITY [J].
BODDE, HE ;
VANAALTEN, EAC ;
JUNGINGER, HE .
JOURNAL OF PHARMACY AND PHARMACOLOGY, 1989, 41 (03) :152-155
[5]
A study on patients treated with polyacrylamide hydrogel injection for facial corrections [J].
Breiting, V ;
Aasted, A ;
Jorgensen, A ;
Opitz, P ;
Rosetzsky, A .
AESTHETIC PLASTIC SURGERY, 2004, 28 (01) :45-53
[6]
Hybrid materials and silica:: drastic control of surfaces and porosity of xerogels via ageing temperature, and influence of drying step on polycondensation at silicon [J].
Cerveau, G ;
Corriu, RJP ;
Framery, E ;
Ghosh, S ;
Mutin, HP .
JOURNAL OF MATERIALS CHEMISTRY, 2002, 12 (10) :3021-3026
[7]
Migration of implants: A problem with injectable polyacrylamide gel in aesthetic plastic surgery [J].
Cheng, NX ;
Xu, SL ;
Deng, H ;
Ding, XB ;
Zhang, XM ;
Wu, DH ;
Zhong, H ;
Sun, ZH .
AESTHETIC PLASTIC SURGERY, 2006, 30 (02) :215-225
[8]
Complications of breast augmentation with injected hydrophilic polyacrylamide gel [J].
Cheng, NX ;
Wang, YL ;
Wang, JH ;
Zhang, XM ;
Zhong, H .
AESTHETIC PLASTIC SURGERY, 2002, 26 (05) :375-382
[9]
Adverse reactions to injectable soft tissue permanent fillers [J].
Christensen, L ;
Breiting, V ;
Janssen, M ;
Vuust, J ;
Hogdall, E .
AESTHETIC PLASTIC SURGERY, 2005, 29 (01) :34-48
[10]
Long-term effects of polyacrylamide hydrogel on human breast tissue [J].
Christensen, LH ;
Breiting, VB ;
Aasted, A ;
Jorgensen, A ;
Kebuladze, I .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2003, 111 (06) :1883-1890