Determination of molecular mass distribution of silicone oils by supercritical fluid chromatography, matrix-assisted laser desorption ionization time-of-flight mass spectrometry and their off-line combination

被引:17
作者
Chmelík, J
Planeta, J
Rehulka, P
Chmelík, J
机构
[1] Acad Sci Czech Republ, Inst Analyt Chem, CS-61142 Brno, Czech Republic
[2] Masaryk Univ, Lab Struct & Dynam Biomol, CS-61137 Brno, Czech Republic
来源
JOURNAL OF MASS SPECTROMETRY | 2001年 / 36卷 / 07期
关键词
silicone oils; determination; polymer size distribution; supercritical fluid chromatography; matrix-assisted laser desorption ionization-time-of-flight mass spectrometry;
D O I
10.1002/jms.179
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Silicone oil samples were characterized by supercritical fluid chromatography (SFC), matrix-assisted laser desorption ionization-time-of-flight mass spectrometry (MALDI-TOF MS), and their off-line combination. SFC was used to separate samples of silicone oils on micropacked capillary columns. The fractions for the identification studies were obtained from SFC runs at defined time intervals, when the restrictor was pulled out from the chromatographic flame ionization detector (FID) and inserted into a,glass vial with acetone. MALDI-TOF MS was used for the identification of individual oligomers in the fractions separated. The molecular mass distributions determined based on SFC and MALDI-TOF MS measurements were compared. From this comparison, it follows that the results are in good agreement. However, certain differences were observed: MALDI-TOF MS was capable of detecting somewhat larger oligomers than the SFC-FID, but the lower molecular mass oligomers were not present in the MALDI spectra. Differences in the region of lower molecular masses can be explained by evaporation of the more volatile low molecular mass oligomers resulting from heating of the sample during the MALDI-TOF MS measurements as a result of the absorption of the laser shot energy. The fact that no high mass discrimination effects of the MALDI-TOF MS measurements, compared with SFC, were observed is very promising for further applications of MALDI-TOF MS in characterizing synthetic polymers of moderate polydispersity. Copyright (C) 2001 John Wiley & Sons, Ltd.
引用
收藏
页码:760 / 770
页数:11
相关论文
共 36 条
[1]  
AUNER N, 1997, ORGANOSILICON CHEM 3, P625
[2]   Mass discrimination effects in an ion detector and other causes for shifts in polymer mass distributions measured by matrix-assisted laser desorption ionization time-of-flight mass spectrometry [J].
Axelsson, J ;
Scrivener, E ;
Haddleton, DM ;
Derrick, PJ .
MACROMOLECULES, 1996, 29 (27) :8875-8882
[3]  
CASLAVSKY J, 2000, 18 INF M MASS SPECT
[4]  
Chmelik J, 1998, CHEM PAP, V52, P360
[5]  
Chmelík J, 2000, HRC-J HIGH RES CHROM, V23, P502
[6]   Packed column supercritical fluid chromatography mass spectroscopy: A review [J].
Combs, MT ;
AshrafKhorassani, M ;
Taylor, LT .
JOURNAL OF CHROMATOGRAPHY A, 1997, 785 (1-2) :85-100
[7]   A FACILE SAMPLE PREPARATION FOR THE ANALYSIS OF SYNTHETIC ORGANIC POLYMERS BY MATRIX-ASSISTED LASER-DESORPTION IONIZATION [J].
DANIS, PO ;
KARR, DE .
ORGANIC MASS SPECTROMETRY, 1993, 28 (08) :923-925
[8]  
DOCEKAL B, UNPUB
[9]  
FJELDSTED JC, 1984, ANAL CHEM, V56, pA619
[10]   Determination of the polydispersity of poly(tetramethylene ether) glycol by means of high-performance liquid chromatography and curve fitting [J].
Graf, H ;
Schulz, G ;
Plitzko, KD .
MACROMOLECULAR CHEMISTRY AND PHYSICS, 1997, 198 (07) :2249-2278