Validity of rapid estimation of glomerular filtration rate in type 2 diabetic patients with normal renal function

被引:30
作者
Nielsen, S [1 ]
Rehling, M
Schmitz, A
Mogensen, CE
机构
[1] Aarhus Kommune Hosp, Med Dept M, DK-8000 Aarhus C, Denmark
[2] Aarhus Kommune Hosp, Dept Clin Physiol & Nucl Med, DK-8000 Aarhus C, Denmark
关键词
diabetic nephropathy; estimated creatinine clearance; glomerular filtration rate; rate of decline of renal function; serum creatinine;
D O I
10.1093/ndt/14.3.615
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Background. Rapid estimation of the renal function is widely used in clinical practice. Methods. The validity of rapid estimation of renal function as well as long-term changes in renal function from the Cockcroft-Gault formula for estimation of creatinine clearance or from serum creatinine measurements was evaluated against the Cr-51-EDTA plasma clearance technique in 36 type 2 diabetic patients with normal renal function followed for 5.2 (2.7-7.5) (mean range) years. Results. Compared with Cr-51-EDTA plasma clearance the Cockcroft-Gault formula significantly underestimated glomerular filtration rate by 21%. The degree of underestimation was observed over the whole range of glomerular filtration rate studied and increased with increasing levels of isotopically measured glomerular filtration rates. Serum creatinine was not significantly associated with glomerular filtration rate. The average long-term change in renal function was significantly overestimated by the Cockcroft-Gault formula (-2.8+/-2.3 mi/min/year) compared with the measured rate (- 1.5 +/-2.5 mi/min/year) (P=0.002). The difference in change rate between the two methods was highest when the measured fall rates were small and tended to disappear in patients with faster fall rates. Changes in serum creatinine correlated significantly, but imprecisely, with the rate of decline of measured glomerular filtration rate (r= -0.48, P=0.003). The variability of the estimated fall rate of renal function was unacceptably high for all approaches. Conclusion. Valid estimates of glomerular filtration rate as well as the rate of change in glomerular filtration rate cannot be obtained by estimation of creatinine clearance from the Cockcroft-Gault formula or from serum creatinine concentration measurements in type 2 diabetic patients with normal renal function.
引用
收藏
页码:615 / 619
页数:5
相关论文
共 27 条
  • [2] CHRISTENSEN CK, 1984, DIABETIC NEPHROPATHY, V3, P92
  • [3] PREDICTION OF CREATININE CLEARANCE FROM SERUM CREATININE
    COCKCROFT, DW
    GAULT, MH
    [J]. NEPHRON, 1976, 16 (01) : 31 - 41
  • [4] PREDICTED CREATININE CLEARANCE TO ASSESS GLOMERULAR-FILTRATION RATE IN CHRONIC RENAL-DISEASE IN HUMANS
    DESANTO, NG
    COPPOLA, S
    ANASTASIO, P
    COSCARELLA, G
    CAPASSO, G
    BELLINI, L
    SANTANGELO, R
    MASSIMO, L
    SICILIANO, A
    [J]. AMERICAN JOURNAL OF NEPHROLOGY, 1991, 11 (03) : 181 - 185
  • [5] FABINY DL, 1971, CLIN CHEM, V17, P696
  • [6] Patterns of renal injury in NIDDM patients with microalbuminuria
    Fioretto, P
    Mauer, M
    Brocco, E
    Velussi, M
    Frigato, F
    Muollo, B
    Sambataro, M
    Abaterusso, C
    Baggio, B
    Crepaldi, G
    Nosadini, R
    [J]. DIABETOLOGIA, 1996, 39 (12) : 1569 - 1576
  • [7] PREDICTING GLOMERULAR FUNCTION FROM ADJUSTED SERUM CREATININE
    GAULT, MH
    LONGERICH, LL
    HARNETT, JD
    WESOLOWSKI, C
    [J]. NEPHRON, 1992, 62 (03) : 249 - 256
  • [8] ESTIMATED CREATININE CLEARANCE IS NOT AN ACCURATE INDEX OF GLOMERULAR-FILTRATION RATE IN NORMOALBUMINURIC DIABETIC-PATIENTS
    GROSS, JL
    SILVEIRO, SP
    DEAZEVEDO, MJ
    PECIS, M
    FRIEDMAN, R
    [J]. DIABETES CARE, 1993, 16 (01) : 407 - 408
  • [9] JONES RH, 1979, LANCET, V1, P1105
  • [10] USE OF THE SERUM CREATININE TO ESTIMATE GLOMERULAR-FILTRATION RATE IN HEALTH AND EARLY DIABETIC NEPHROPATHY
    LEMANN, J
    BIDANI, AK
    BAIN, RP
    LEWIS, EJ
    ROHDE, RD
    [J]. AMERICAN JOURNAL OF KIDNEY DISEASES, 1990, 16 (03) : 236 - 243