New polyaniline-based potentiometric biosensor for pesticides detection

被引:21
作者
Ivanov, AN [1 ]
Evtugyn, GA
Lukachova, LV
Karyakina, EE
Budnikov, HC
Kiseleva, SG
Orlov, AV
Karpacheva, GP
Karyakin, AA
机构
[1] Kazan VI Lenin State Univ, Dept Analyt Chem, Kazan, Russia
[2] Kazan VI Lenin State Univ, Appl Ecol Dept, Kazan, Russia
[3] Moscow MV Lomonosov State Univ, Fac Chem, Moscow, Russia
[4] Russian Acad Sci, AV Topchiev Petrochem Synth Inst, Moscow, Russia
基金
俄罗斯基础研究基金会;
关键词
cholinesterase; inhibition; pesticide; polyaniline; potentiometric biosensor;
D O I
10.1109/JSEN.2003.814647
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A cholinesterase potentiometric sensor based on a glassy carbon electrode modified with processible polyaniline has been developed and explored for the detection of organophosphorus and carbamic pesticides. Acetyl- and butyrylcholinesterase from various sources were immobilized on the surface of a polyaniline modified electrode by cross-linking with glutaraldehyde. Polyaniline modification made it possible to obtain a reversible pH response of about 86-mV/pH unit and to improve the analytical and operational characteristics of substrate and inhibitor detection. The sensitivity of pesticide detection depends on both the source of the enzyme and its activity and on pesticide hydrophobicity. The detection limits of the pesticides investigated (Trichlorfon, 1.5(.)10(-7) mol/l, Coumaphos, 5(.)10(-9) mol/l, Methiocarb, 8(.)10(-7) mol/l, Aldicarb, 2(.)10(-7) mol/l) were found lower than those obtained with other similar cholinesterase sensors. The possibility for the detection of the trace amounts of pesticides in river waters and grape juice with cholinesterase sensors developed has been established on model samples.
引用
收藏
页码:333 / 340
页数:8
相关论文
共 29 条
[1]   Analyses of pesticides and their metabolites in foods and drinks [J].
Ahmed, FE .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2001, 20 (11) :649-661
[2]  
[Anonymous], RUSS CHEM REV
[3]   Aminated membranes for pH detection obtained by photochemical vapor deposition technique [J].
Baccar, ZM ;
JaffrezicRenault, N ;
Lemiti, M .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1997, 144 (11) :3989-3992
[4]   A disposable multielectrode biosensor for rapid simultaneous detection of the insecticides paraoxon and carbofuran at high resolution [J].
Bachmann, TT ;
Schmid, RD .
ANALYTICA CHIMICA ACTA, 1999, 401 (1-2) :95-103
[5]   Sub-optical-cycle coherent control in nonlinear optics [J].
Bartels, Randy ;
Backus, Sterling ;
Vdovin, Gleb ;
Christov, Ivan P. ;
Murnane, Margaret M. ;
Kapteyn, Henry C. .
Optics and Photonics News, 2000, 11 (12) :23-24
[6]  
BOLIN P, 1999, FQPA TARGETED PEST R
[7]   Electrochemical biosensors for inhibitor determination: Selectivity and sensitivity control [J].
Budnikov, HC ;
Evtugyn, GA .
ELECTROANALYSIS, 1996, 8 (8-9) :817-820
[8]   EFFECT OF SOLVENTS AND COSOLVENTS ON THE PROCESSIBILITY OR POLYANILINE .1. SOLUBILITY AND CONDUCTIVITY STUDIES [J].
CAO, Y ;
QIU, JJ ;
SMITH, P .
SYNTHETIC METALS, 1995, 69 (1-3) :187-190
[9]   Amperometric biosensors based on nafion coated screen-printed electrodes for the determination of cholinesterase inhibitors [J].
Gogol, EV ;
Evtugyn, GA ;
Marty, JL ;
Budnikov, HC ;
Winter, VG .
TALANTA, 2000, 53 (02) :379-389
[10]   Non-aqueous flow-injection determination of atrazine by inhibition of immobilized tyrosinase [J].
Hipólito-Moreno, A ;
León-González, ME ;
Pérez-Arribas, LV ;
Polo-Díez, LM .
ANALYTICA CHIMICA ACTA, 1998, 362 (2-3) :187-192