Reliability of assessing interproximal bone loss by digital radiography: intrabony defects

被引:46
作者
Wolf, B
von Bethlenfalvy, E
Hassfeld, S
Staehle, HJ
Eickholz, P
机构
[1] Univ Heidelberg, Dent Clin, Dept Oral & Maxillofacial Surg, D-69120 Heidelberg, Germany
[2] Univ Heidelberg, Dent Clin, Dept Operat Dent & Periodontol, D-69120 Heidelberg, Germany
[3] Univ Heidelberg, Dent Clin, Sect Periodontol, D-69120 Heidelberg, Germany
关键词
digital radiology; intrabony defects; intraindividual/interindividual reproducibility; validity; linear measurements;
D O I
10.1034/j.1600-051x.2001.028009869.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: The aim of the present study was to assess the reproducibility and validity of linear measurements of interproximal bone loss in intrabony defects on digitized radiographic images after application of different filters and magnifications. Methods: Immediately before surgery 50 radiographs of 50 periodontally diseased teeth exhibiting interproximal intrabony defects were obtained by a standardized technique in 50 patients. Intrasurgically the distances from the cemento-enamel-junction (CEJ) to the alveolar crest (AC) and from the CEJ to the deepest extension of the bony defect (BD) were assessed. All radiographs were digitized by a flatbed scanner (resolution: 600 X 1200 dpi). Using the FRIACOM-soft ware, the linear distances CEJ to AC and CEJ to BD were measured at 50 intrabony defects on digitized but unchanged radiographic images and also after use of 2 different basic image processing modes (filters: enhancement of grey level differences, spreading of grey values) with 7-fold and 14-fold magnification by 2 different examiners. Results: Repeated measures MANOVA revealed reproducibility of the measurement of the distance CEJ to AC to be significantly influenced by examiner (p = 0.027) and filter in combination with the height of 2 wall component of the intrabony defect (p = 0.066). For the distance CEJ to BD filters had significant influence on reproducibility in correlation with vertical angulation difference (p = 0.001). On the average in this study radiographic measurements tended to overestimate the amount of bone loss as assessed by intrasurgical measurements (CEJ-AC: 0.74-1.91 mm; CEJ-DB: -0.04-0.77 mm). Validity of measurement of the distance CEJ-AC was shown to be significantly influenced by the depth of the intrabony defect (p < 0.003). Validity of the distance CEJ-BD was significantly influenced by intrasurgically assessed bone loss (p = 0.029), horizontal angulation (p = 0.066). Filters influenced the validity only in combination with examiner (p < 0.001). Conclusions: In this study, the chosen digital manipulations (filters: spreading, structure) of radiographic images failed to result in statistically significantly more reproducible or valid measurements of interproximal bone loss within intrabony defects when compared to the digitized but unchanged images. All radiographic assessments on the digitized images except for use of enhancement of grey level differences (structure) came close to the intrasurgical gold standard.
引用
收藏
页码:869 / 878
页数:10
相关论文
共 21 条
[1]   COMPARISON OF PANORAMIC AND INTRAORAL RADIOGRAPHY AND POCKET PROBING FOR THE MEASUREMENT OF THE MARGINAL BONE LEVEL [J].
AKESSON, L ;
HAKANSSON, J ;
ROHLIN, M .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1992, 19 (05) :326-332
[2]   A COMPUTER-ASSISTED METHOD FOR MAKING LINEAR RADIOGRAPHIC MEASUREMENTS USING STORED REGIONS OF INTEREST [J].
BENN, DK .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1992, 19 (07) :441-448
[3]   FALSE POSITIVE RATES IN THE DETERMINATION OF CHANGES IN PROBING DEPTH-RELATED PERIODONTAL MEASUREMENTS [J].
COHEN, ME ;
RALLS, SA .
JOURNAL OF PERIODONTAL RESEARCH, 1988, 23 (03) :161-165
[4]   A METHOD FOR THE GEOMETRIC AND DENSITOMETRIC STANDARDIZATION OF INTRAORAL RADIOGRAPHS [J].
DUCKWORTH, JE ;
JUDY, PF ;
GOODSON, JM ;
SOCRANSKY, SS .
JOURNAL OF PERIODONTOLOGY, 1983, 54 (07) :435-440
[5]   Digital radiography of interproximal caries: Effect of different filters [J].
Eickholz, P ;
Kolb, I ;
Lenhard, M ;
Hassfeld, S ;
Staehle, HJ .
CARIES RESEARCH, 1999, 33 (03) :234-241
[6]   Digital radiography of interproximal bone loss; validity of different filters [J].
Eickholz, P ;
Riess, T ;
Lenhard, M ;
Hassfeld, S ;
Staehle, HJ .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1999, 26 (05) :294-300
[7]   Accuracy of radiographic assessment of interproximal bone loss in intrabony defects using linear measurements [J].
Eickholz, P ;
Hausmann, E .
EUROPEAN JOURNAL OF ORAL SCIENCES, 2000, 108 (01) :70-73
[8]  
Eickholz P, 1999, J CLIN PERIODONTOL, V26, P769
[9]   Radiographic evaluation of bone regeneration following periodontal surgery with or without expanded polytetrafluoroethylene barriers [J].
Eickholz, P ;
Benn, DK ;
Staehle, HJ .
JOURNAL OF PERIODONTOLOGY, 1996, 67 (04) :379-385
[10]   Validity of radiographic measurement of interproximal bone loss [J].
Eickholz, P ;
Kim, TS ;
Benn, DK ;
Staehle, HJ .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1998, 85 (01) :99-106