Virus removal by ceramic membrane microfiltration with coagulation pretreatment

被引:23
作者
Matsui, Y [1 ]
Matsushita, T [1 ]
Inoue, T [1 ]
Yamamoto, M [1 ]
Hayashi, Y [1 ]
Yonekawa, H [1 ]
Tsutsumi, Y [1 ]
机构
[1] Gifu Univ, Dept Civil Engn, Gifu 5011193, Japan
来源
MEMBRANES IN DRINKING AND INDUSTRIAL WATER PRODUCTION III | 2003年
关键词
ceramic membrane; coagulation; microfiltration; virus;
D O I
10.2166/ws.2003.0154
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The performance and mechanism of virus removal by microfiltration with coagulation pretreatment were investigated. We confirmed the unexpectedly high performance of virus removal for two types of ceramic membrane system: a positive pressure-driven dead-end filtration with inside-out configuration and a vacuum pressure-driven dead-end immersed filtration with outside-in configuration. Virus removals by both systems were more than 7 logs, although the size of the tested Obeta virus (23 nm) was much smaller than the membrane nominal pore size of 100 nm. The virus inactivation by the addition of the coagulant (PACl) and the virus adsorption onto the floc retained on the membrane surface mainly contributed the virus removal. No virus accumulation in the retentate was observed, possibly due to the virus inactivation by the coagulant.
引用
收藏
页码:93 / 99
页数:7
相关论文
共 5 条
[1]  
[Anonymous], STANDARD METHODS EXA
[2]  
COFFEY BM, 1993, P MEMBR TECHN C AM W, P373
[3]  
JACANGELO JG, 1995, J AM WATER WORKS ASS, V87, P107
[4]   DISINFECTION AND CLARIFICATION OF TREATED SEWAGE BY ADVANCED MICROFILTRATION [J].
KOLEGA, M ;
GROHMANN, GS ;
CHIEW, RF ;
DAY, AW .
WATER SCIENCE AND TECHNOLOGY, 1991, 23 (7-9) :1609-1618
[5]  
MATSUI Y, 2001, IWA 2 WORLD WAT C BE