Restenosis of endovascular stents from stent compression

被引:97
作者
Rosenfield, K [1 ]
Schainfeld, R [1 ]
Pieczek, A [1 ]
Haley, L [1 ]
Isner, JM [1 ]
机构
[1] TUFTS UNIV,SCH MED,ST ELIZABETHS MED CTR,DEPT BIOMED RES,BOSTON,MA 02135
关键词
D O I
10.1016/S0735-1097(96)00498-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives, We sought to determine the basis for restenosis within superficial femoral arteries (SFAs) and hemodialysis conduits treated with balloon-expandable stents, Background. Use of stents within coronary and peripheral vessels continues to increase exponentially, The mechanism of restenosis within stents placed at various vascular sites is not well understood, In particular, the implications of deploying a balloon-expandable stent in a compressible site are not well understood, Methods. After the serendipitous detection of stent deformation during intravascular ultrasound (IVUS) examination of a restenosed dialysis fistula, we evaluated a consecutive series of patients with stents placed in compressible vascular sites, including the SFA (sis patients) and hemodialysis fistulae (five patients), Clinical, angiographic and IVUS examinations were performed to evaluate mechanisms of restenosis, Results, Stent compression was identified as the principal cause of restenosis in all dialysis conduits and SFAs, Stent deformity was not reliably identified by angiography; however, IVUS identified compression of two forms: eccentric deformation, implicating two-point compressive force, and complete circumferential encroachment of stent struts around the catheter, suggesting multidirectional compressive force, Despite redilation, secondary restenosis resulting from recurrent compression recurred in most sites, Conclusions. Restenosis within balloon-expandable endovascular stents may occur as a result of stent compression, a phenomenon readily detected by IVUS, but often not by angiography. These findings have significant implications for the use of balloon-expandable stents within vascular sites subject to extrinsic compression, such as hemodialysis conduits, the adductor canal segment of the SFA and carotid arteries, (C) 1997 by the American College of Cardiology.
引用
收藏
页码:328 / 338
页数:11
相关论文
共 48 条
[1]  
BECKER GJ, 1991, CIRCULATION, V83, P122
[2]   ANGIOPLASTY-INDUCED DISSECTIONS IN HUMAN ILIAC ARTERIES - MANAGEMENT WITH PALMAZ BALLOON-EXPANDABLE INTRALUMINAL STENTS [J].
BECKER, GJ ;
PALMAZ, JC ;
REES, CR ;
EHRMAN, KO ;
LALKA, SG ;
DALSING, MC ;
CIKRIT, DF ;
MCLEAN, GK ;
BURKE, DR ;
RICHTER, GM ;
NOELDGE, G ;
GARCIA, O ;
WALLER, BF ;
CASTANEDAZUNIGA, WR .
RADIOLOGY, 1990, 176 (01) :31-38
[3]   SHOULD METALLIC VASCULAR STENTS BE USED TO TREAT CEREBROVASCULAR OCCLUSIVE DISEASES [J].
BECKER, GJ .
RADIOLOGY, 1994, 191 (02) :309-312
[4]  
BJAMASON H, 1993, AM J ROENTGENOL, V160, P1123
[5]  
BONNER RF, 1991, CIRCULATION S2, V84, P197
[6]   PRELIMINARY-OBSERVATIONS ON THE USE OF THE PALMAZ STENT IN THE DISTAL PORTION OF THE ABDOMINAL-AORTA [J].
DIETHRICH, EB ;
SANTIAGO, O ;
GUSTAFSON, G ;
HEUSER, RR .
AMERICAN HEART JOURNAL, 1993, 125 (02) :490-501
[7]  
DIETHRICH EB, 1995, CIRCULATION, V92, P383
[8]   RESTENOSIS AFTER PLACEMENT OF PALMAZ-SCHATZ STENTS IN NATIVE CORONARY-ARTERIES - INITIAL RESULTS OF A MULTICENTER EXPERIENCE [J].
ELLIS, SG ;
SAVAGE, M ;
FISCHMAN, D ;
BAIM, DS ;
LEON, M ;
GOLDBERG, S ;
HIRSHFELD, JW ;
CLEMAN, MW ;
TEIRSTEIN, PS ;
WALKER, C ;
BAILEY, S ;
BUCHBINDER, M ;
TOPOL, EJ ;
SCHATZ, RA .
CIRCULATION, 1992, 86 (06) :1836-1844
[9]  
Elson J D, 1991, J Vasc Interv Radiol, V2, P215, DOI 10.1016/S1051-0443(91)72285-9
[10]   EFFECT OF INTRACORONARY STENTING ON INTIMAL DISSECTION AFTER BALLOON ANGIOPLASTY - RESULTS OF QUANTITATIVE AND QUALITATIVE CORONARY ANALYSIS [J].
FISCHMAN, DL ;
SAVAGE, MP ;
LEON, MB ;
SCHATZ, RA ;
ELLIS, SG ;
CLEMAN, MW ;
TEIRSTEIN, P ;
WALKER, CM ;
BAILEY, S ;
HIRSHFELD, JW ;
GOLDBERG, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (06) :1445-1451