This paper investigates a fault-tolerant three-phase ac/ac converter topology. With such a topology when either one leg of the input rectifier of one leg of the output inverter is lost the power flow between the grid and the load can still be controlled effectively. The topology proposed and its operating principles are presented. The suitable control strategy for the post-fault converter is developed. Experimental results are presented.
引用
收藏
页码:1077 / 1084
页数:8
相关论文
共 18 条
[1]
Single current sensor technique in the DC link of three-phase PWM-VS inverters: A review and a novel solution [J].
Blaabjerg, F ;
Pedersen, JK ;
Jaeger, U ;
Thoegersen, P .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1997, 33 (05) :1241-1253
[2]
Experimental fault-tolerant control of a PMSM drive [J].
Bolognani, S ;
Zordan, M ;
Zigliotto, M .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2000, 47 (05) :1134-1141
[3]
An induction motor drive system with improved fault tolerance [J].
Corrêa, MBD ;
Jacobina, CB ;
da Silva, ERC ;
Lima, AMN .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2001, 37 (03) :873-879
[4]
DEBEBE K, 1991, CONFERENCE RECORD OF THE 1991 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING, VOLS 1 AND 2, P368, DOI 10.1109/IAS.1991.178181
[5]
PULSEWIDTH MODULATION FOR ELECTRONIC POWER CONVERSION [J].
HOLTZ, J .
PROCEEDINGS OF THE IEEE, 1994, 82 (08) :1194-1214
[6]
Digital scalar pulse-width modulation: A simple approach to introduce non-sinusoidal modulating waveforms [J].
Jacobina, CB ;
Lima, AMN ;
da Silva, ERC ;
Alves, RNC ;
Seixas, PF .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2001, 16 (03) :351-359
[7]
Jacobina CB, 2001, APPL POWER ELECT CO, P378, DOI 10.1109/APEC.2001.911675
[8]
IMPROVED RELIABILITY IN SOLID-STATE AC DRIVES BY MEANS OF MULTIPLE INDEPENDENT PHASE-DRIVE UNITS [J].
JAHNS, TM .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1980, 16 (03) :321-331
[9]
ONLINE SEARCH BASED PULSATING TORQUE COMPENSATION OF A FAULT MODE SINGLE-PHASE VARIABLE FREQUENCY INDUCTION-MOTOR DRIVE [J].
KASTHA, D ;
BOSE, BK .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1995, 31 (04) :802-811
[10]
Kim GT, 1995, IEEE IND APPLIC SOC, P2327, DOI 10.1109/IAS.1995.530598