The Current Performance of the Wide Range (90-2500eV) Soft X-ray Beamline at the Australian Synchrotron

被引:180
作者
Cowie, B. C. C. [1 ]
Tadich, A. [1 ]
Thomsen, L. [1 ]
机构
[1] Australian Synchrotron, Clayton, Vic, Australia
来源
SRI 2009: THE 10TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION | 2010年 / 1234卷
关键词
Synchrotron Radiation; Beamline; Plane-grating monochromator;
D O I
10.1063/1.3463197
中图分类号
O59 [应用物理学];
学科分类号
摘要
The Soft X-ray beamline at the Australian synchrotron has been constructed around a collimated light Plane Grating Monochromator taking light from an Elliptically Polarized Undulator (EPU). The beamline covers a wide photon energy range between 90 to 2500 eV, using two gratings of 250 l/mm and 1200 l/mm. At present the output from the monochromator is directed into one branchline with a dedicated UHV endstation.. The measured performance of the beamline in flux and resolution is shown to be very close to that of theoretical calculations.