Interobserver variation of colour Duplex scanning of the popliteal, tibial and pedal arteries

被引:25
作者
Koelemay, MJW [1 ]
Legemate, DA [1 ]
van Gurp, JA [1 ]
de Vos, H [1 ]
Balm, R [1 ]
Jacobs, MJHM [1 ]
机构
[1] Acad Med Ctr, Dept Surg, NL-1100 DE Amsterdam, Netherlands
关键词
Duplex scanning; interobserver variation; lower leg arteries;
D O I
10.1053/ejvs.2000.1306
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objectives: to determine interobserver variation in the measurement of Peak Systolic Velocity (PSV) and grading of disease by means of Duplex scanning (DS) in the popliteal, tibial and pedal arteries. Design: prospective validation study. Materials: twenty-four consecutive patients with severe claudication (n = 6), ischaemic rest pain (n = 11) and tissue loss in = 7). Methods: two vascular technologists independently examined the popliteal, tibial and pedal arteries. The PSV was recorded in 15 arterial segments that were graded with B-mode and Doppler parameters as fully patent, severely diseased or occluded. Concordance in PSV recordings was expressed as intraclass correlation coefficients (ICC). Agreement in artery assessment was expressed as weighted K-values. Results: the ICC br PSV measurements was 0.90 (95% CI, 0.86 to 0.93) within the popliteal and tibial arteries and 0.64 (95% CI, 0.37 to 0.81) within the pedal arteries. Agreement for grading disease was good within the popliteal and tibial arteries (K 0.66, 95% CI, 0.58 to 0.74), and moderate within the pedal arteries (K 0.54, 95% CI 0.33 to 0.74). The presence of diabetes or stage of disease did not influence interobserver agreement. Conclusion: interobserver agreement of DS is good within the popliteal and tibial arteries and moderate within the pedal arteries.
引用
收藏
页码:160 / 164
页数:5
相关论文
共 15 条
[1]  
ALTMAN DG, 1995, PRACTICAL STAT MED R, P403
[2]  
FLEISS SL, 1981, STAT METHODS RATES P, P225
[3]   USERS GUIDES TO THE MEDICAL LITERATURE .3. HOW TO USE AN ARTICLE ABOUT A DIAGNOSTIC-TEST .A. ARE THE RESULTS OF THE STUDY VALID [J].
JAESCHKE, R ;
GUYATT, G ;
SACKETT, DL .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1994, 271 (05) :389-391
[4]   Value of duplex scanning in evaluation of crural and foot arteries in limbs with severe lower limb ischaemia - A prospective comparison with angiography [J].
Karacagil, S ;
Lofberg, AM ;
Granbo, A ;
Lorelius, LE ;
Bergquist, D .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1996, 12 (03) :300-303
[5]  
Koelemay MJW, 1997, BRIT J SURG, V84, P1115, DOI 10.1002/bjs.1800840822
[6]   Can cruropedal colour duplex scanning and pulse generated run-off replace angiography in candidates for distal bypass surgery? [J].
Koelemay, MJW ;
Legemate, DA ;
de Vos, H ;
van Gurp, JA ;
Reekers, JA ;
Jacobs, MJHM .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1998, 16 (01) :13-18
[7]   CLINICAL BIOSTATISTICS .54. THE BIOSTATISTICS OF CONCORDANCE [J].
KRAMER, MS ;
FEINSTEIN, AR .
CLINICAL PHARMACOLOGY & THERAPEUTICS, 1981, 29 (01) :111-123
[8]   Value of color duplex sonography for evaluation of tibioperoneal arteries in patients with femoropopliteal obstruction: A prospective comparison with anterograde intraarterial digital subtraction angiography [J].
Larch, E ;
Minar, E ;
Ahmadi, R ;
Schnurer, G ;
Schneider, B ;
Stumpflen, A ;
Ehringer, H .
JOURNAL OF VASCULAR SURGERY, 1997, 25 (04) :629-636
[9]   ACCURACY AND REPRODUCIBILITY OF DUPLEX ULTRASONOGRAPHY IN GRADING FEMOROPOPLITEAL STENOSES [J].
LENG, GC ;
WHYMAN, MR ;
DONNAN, PT ;
RUCKLEY, CV ;
GILLESPIE, I ;
FOWKES, FGR ;
ALLAN, PL .
JOURNAL OF VASCULAR SURGERY, 1993, 17 (03) :510-517
[10]   Duplex ultrasound scanning defines operative strategies for patients with limb-threatening ischemia [J].
Ligush, J ;
Reavis, SW ;
Preisser, JS ;
Hansen, KJ .
JOURNAL OF VASCULAR SURGERY, 1998, 28 (03) :482-490