Morphological characteristics of P waves during selective pulmonary vein pacing

被引:61
作者
Yamane, T [1 ]
Shah, DC [1 ]
Peng, JT [1 ]
Jaïs, P [1 ]
Hocini, M [1 ]
Deisenhofer, I [1 ]
Choi, KJ [1 ]
Macle, L [1 ]
Clémenty, J [1 ]
Haïssaguerre, M [1 ]
机构
[1] Hop Cardiol Haut Leveque, F-33604 Bordeaux, France
关键词
D O I
10.1016/S0735-1097(01)01578-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES We sought to assess the value of 12-lead electrocardiogram (ECG) P-wave morphology to recognize the paced pulmonary vein (PV). BACKGROUND Prediction of arrhythmogenic PVs producing ectopy or initiating atrial fibrillation (AF) using 12-lead ECG may facilitate curative ablation. METHODS In 30 patients P-wave configurations were studied during sinus rhythm and during pacing at six sites from the four PVs: top and bottom of each superior PV and both inferior PVS. The P-wave amplitude, duration and morphology were assessed, and predictive accuracies were calculated for the most significant parameters. An algorithm predicting the paced PV was developed and prospectively evaluated in a different population of 20 patients. RESULTS Three criteria were used to distinguish right from left PV: 1) a positive P-wave in lead aVL and the amplitude of P-wave in. lead 1 greater than or equal to 50 muV indicated right PV origin (specificity 100% and 97%, respectively); 2) a notched P-wave in lead II was a predictor of left PV origin (specificity 95%); and 3) the amplitude ratio of lead III/II and the duration of positivity in lead V-1 were also helpful in distinguishing left versus right PV origin. In addition, superior PVs could be distinguished from inferior according to the amplitude in lead II (greater than or equal to 100 muV). In prospective evaluation, an algorithm based on the above four criteria identified 93% of left versus right PV and totally 79% of the specific PVs paced. CONCLUSIONS Pacing from the different PVs produced a P-wave with distinctive characteristics that could be used as criteria in an algorithm to identify the PV of origin with an accuracy of 79%. (J Am Coll Cardiol 2001;38:1505-10) (C) 2001 by the American College of Cardiology.
引用
收藏
页码:1505 / 1510
页数:6
相关论文
共 10 条
  • [1] Initiation of atrial fibrillation by ectopic beats originating from the pulmonary veins - Electrophysiological characteristics, pharmacological responses, and effects of radiofrequency ablation
    Chen, SA
    Hsieh, MH
    Tai, CT
    Tsai, CF
    Prakash, VS
    Yu, WC
    Hsu, TL
    Ding, YA
    Chang, MS
    [J]. CIRCULATION, 1999, 100 (18) : 1879 - 1886
  • [2] Electrophysiological end point for catheter ablation of atrial fibrillation initiated from multiple pulmonary venous foci
    Haïssaguerre, M
    Jaïs, P
    Shah, DC
    Garrigue, S
    Takahashi, A
    Lavergne, T
    Hocini, M
    Peng, JT
    Roudaut, R
    Clementy, J
    [J]. CIRCULATION, 2000, 101 (12) : 1409 - 1417
  • [3] Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins
    Haïssaguerre, M
    Jaïs, P
    Shah, DC
    Takahashi, A
    Hocini, M
    Quiniou, G
    Garrigue, S
    Le Mouroux, A
    Le Métayer, P
    Clémenty, J
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (10) : 659 - 666
  • [4] Non-invasive assessment of the atrial cycle length during atrial fibrillation in man:: introducing, validating and illustrating a new ECG method
    Holm, M
    Pehrson, S
    Ingemansson, M
    Sörnmo, L
    Johansson, R
    Sandhall, L
    Sunemark, M
    Smideberg, B
    Olsson, SB
    [J]. CARDIOVASCULAR RESEARCH, 1998, 38 (01) : 69 - 81
  • [5] Defibrillation-guided radiofrequency ablation of atrial fibrillation secondary to an atrial focus
    Lau, CP
    Tse, HF
    Ayers, GM
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 33 (05) : 1217 - 1226
  • [6] P-WAVES DURING ECTOPIC ATRIAL RHYTHMS IN MAN - STUDY UTILIZING ATRIAL-PACING WITH FIXED ELECTRODES
    MACLEAN, WAH
    KARP, RB
    KOUCHOUKOS, NT
    JAMES, TN
    WALDO, AL
    [J]. CIRCULATION, 1975, 52 (03) : 426 - 434
  • [7] Spatial resolution of atrial pace mapping as determined by unipolar atrial pacing at adjacent sites
    Man, KC
    Chan, KK
    Kovack, P
    Goyal, R
    Bogun, F
    Harvey, M
    Daoud, E
    Strickberger, SA
    Morady, F
    [J]. CIRCULATION, 1996, 94 (06) : 1357 - 1363
  • [8] Regional endocardial mapping of spontaneous and induced atrial fibrillation in patients with heart disease and refractory atrial fibrillation
    Saksena, S
    Prakash, A
    Krol, RB
    Shankar, A
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1999, 84 (08) : 880 - 889
  • [9] Simple electrocardiographic criteria for identifying the site of origin of focal right atrial tachycardia
    Tada, H
    Nogami, A
    Naito, S
    Suguta, M
    Nakatsugawa, M
    Horie, Y
    Tomita, T
    Hoshizaki, H
    Oshima, S
    Taniguchi, K
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (11): : 2431 - 2439
  • [10] USE OF P-WAVE CONFIGURATION DURING ATRIAL TACHYCARDIA TO PREDICT SITE OF ORIGIN
    TANG, CW
    SCHEINMAN, MM
    VANHARE, GF
    EPSTEIN, LM
    FITZPATRICK, AP
    LEE, RJ
    LESH, MD
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 26 (05) : 1315 - 1324