Contrast enhancement in emission tomography by way of synergistic PET/CT image combination

被引:20
作者
Boussion, N. [1 ]
Hatt, M. [1 ]
Lamare, F. [2 ]
Le Rest, C. Cheze [1 ]
Visvikis, D. [1 ]
机构
[1] CHU Morvan, INSERM, U650, LaTIM, F-29609 Brest, France
[2] Univ London Imperial Coll Sci Technol & Med, CSC PET Cardiol, MRC, Ctr Clin Sci, London, England
关键词
PET; CT; image display; image combination; wavelets;
D O I
10.1016/j.cmpb.2007.12.009
中图分类号
TP39 [计算机的应用];
学科分类号
081203 [计算机应用技术]; 0835 [软件工程];
摘要
The display of image fusion is well accepted as a powerful tool in visual image analysis and comparison. in clinical practice, this is a mandatory step when studying images from a dual PET/CT scanner. However, the display methods that are implemented on most work-stations simply show both images side by side, in separate and synchronized windows. Sometimes images are presented superimposed in a single window, preventing the user from doing quantitative analysis. In this article a new image fusion scheme is presented, allowing performing quantitative analysis directly on the fused images. Methods: The objective is to preserve the functional information provided by PET while incorporating details of higher resolution from the CT image. The process relies on a discrete wavelet-based image merging: both images are decomposed into successive details layers by using the "a trous" transform. This algorithm performs wavelet decomposition of images and provides coarser and coarser spatial resolution versions of them. The high-spatial frequencies of the CT, or details, can be easily obtained at any level of resolution. A simple model is then inferred to compute the lacking details of the PET scan from the high frequency detail layers of the CT. These details are then incorporated in the PET image on a voxel-to-voxel basis, giving the fused PET/CT image. Results: Aside from the expected visual enhancement, quantitative comparison of initial PET and CT images with fused images was performed in 12 patients. The obtained results were in accordance with the objectives of the study, in the sense that the organs' mean intensity in PET was preserved in the fused image. Conclusion: This alternative approach to PET/CT fusion display should be of interest for people interested in a more quantitative aspect of image fusion. The proposed method is actually complementary to more classical visualization tools. (c) 2008 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:191 / 201
页数:11
相关论文
共 19 条
[1]
[Anonymous], CBMS NSF REGIONAL C
[2]
Chan C, 2005, IEEE NUCL SCI CONF R, P2618
[3]
DUTILLEUX P., 1987, C OND METH TEMPS FRE, P298
[4]
Remote sensing analysis of the Gorge of the Nile, Ethiopia with emphasis on Dejen-Gohatsion region [J].
Gani, NDS ;
Abdelsalam, MG .
JOURNAL OF AFRICAN EARTH SCIENCES, 2006, 44 (02) :135-150
[5]
HOLDSCHNEIDER R, 1989, WAVELETS
[6]
Automated detection of fecal contamination of apples based on multispectral fluorescence image fusion [J].
Kim, MS ;
Lefcourt, AM ;
Chen, YR ;
Tao, Y .
JOURNAL OF FOOD ENGINEERING, 2005, 71 (01) :85-91
[7]
Automated comparison of firearm bullets [J].
Leon, FP .
FORENSIC SCIENCE INTERNATIONAL, 2006, 156 (01) :40-50
[8]
A THEORY FOR MULTIRESOLUTION SIGNAL DECOMPOSITION - THE WAVELET REPRESENTATION [J].
MALLAT, SG .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1989, 11 (07) :674-693
[9]
Fingerprint verification by fusion of optical and capacitive sensors [J].
Marcialis, GL ;
Roli, F .
PATTERN RECOGNITION LETTERS, 2004, 25 (11) :1315-1322
[10]
Robust memory-efficient data level information fusion of multi-modal biometric images [J].
Noore, Afzel ;
Singh, Richa ;
Vatsa, Mayank .