Selective functionalisation of PDMS-based photonic lab on a chip for biosensing

被引:30
作者
Ibarlucea, Bergoi [1 ]
Fernandez-Sanchez, Cesar [1 ]
Demming, Stefanie [2 ]
Buettgenbach, Stephanus [2 ]
Llobera, Andreu [1 ]
机构
[1] IMB CNM CSIC, Inst Microelect Barcelona, Bellaterra 08193, Spain
[2] Tech Univ Carolo Wilhelmina Braunschweig, Inst Mikrotech, D-38124 Braunschweig, Germany
基金
欧洲研究理事会;
关键词
SURFACE MODIFICATION; OXYGEN PLASMA; HOLLOW PRISMS; POLY(DIMETHYLSILOXANE); MICROCHANNEL;
D O I
10.1039/c0an00941e
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学];
摘要
A comparative study of different approaches for the selective immobilisation of biomolecules on the surface of poly(dimethylsiloxane) (PDMS) is reported. The motivation of this work is to set a robust and reliable protocol for the easy implementation of a biosensor device in a PDMS-based photonic lab-on-a-chip (PhLoC). A hollow prism configuration, previously reported for the colorimetric detection of analytes was chosen for this study. Here, the inner walls of the hollow prism were initially modified by direct adsorption of either polyethylene glycol (PEG) or polyvinyl alcohol (PVA) linear polymers as well as by carrying out a light chemical oxidation step. All these processes introduced hydroxyl groups on the PDMS surface to a different extent. The hydroxyl groups were further silanised using a silane containing an aldehyde end-group. The interaction between this group and a primary amine moiety enabled the selective covalent attachment of a biomolecule on the PDMS surface. A thorough structural characterisation of the resulting modified-PDMS substrates was carried out by contact angle measurements, X-ray photoelectron spectroscopic (XPS) analysis and atomic force microscopy (AFM) imaging. Using horseradish peroxidase as a model recognition element, different biosensor approaches based on each modification process were developed for the detection of hydrogen peroxide target analyte in a concentration range from 0.1 mu M to 100 mu M. The analytical performance was similar in all cases, a linear concentration range between 0.1 mu M and 24.2 mu M, a sensitivity of 0.02 a.u. mu M-1 and a limit of detection around 0.1 mu M were achieved. However, important differences were observed in the reproducibility of the devices as well as in their operational stability, which was studied over a period of up to two months. Considering all these studies, the PVA-modified approach appeared to be the most suitable one for the simple fabrication of a biosensor device integrated in a PDMS PhLoC.
引用
收藏
页码:3496 / 3502
页数:7
相关论文
共 29 条
[1]
Surface modification for enhancing antibody binding on polymer-based microfluidic device for enzyme-linked immunosorbent assay [J].
Bai, Yunling ;
Koh, Chee Guan ;
Boreman, Megan ;
Juang, Yi-Je ;
Tang, I-Ching ;
Lee, L. James ;
Yang, Shang-Tian .
LANGMUIR, 2006, 22 (22) :9458-9467
[2]
UV/ozone modification of poly(dimethylsiloxane) microfluidic channels [J].
Berdichevsky, Y ;
Khandurina, J ;
Guttman, A ;
Lo, YH .
SENSORS AND ACTUATORS B-CHEMICAL, 2004, 97 (2-3) :402-408
[3]
Hydrophilization and hydrophobic recovery of PDMS by oxygen plasma and chemical treatment - An SEM investigation [J].
Bodas, Dhananjay ;
Khan-Malek, Chantal .
SENSORS AND ACTUATORS B-CHEMICAL, 2007, 123 (01) :368-373
[4]
Reduction of Non-Specific Protein Adsorption Using Poly(ethylene) Glycol (PEG) Modified Polyacrylate Hydrogels In Immunoassays for Staphylococcal Enterotoxin B Detection [J].
Charles, Paul T. ;
Stubbs, Veronte R. ;
Soto, Carissa M. ;
Martin, Brett D. ;
White, Brandy J. ;
Taitt, Chris R. .
SENSORS, 2009, 9 (01) :645-655
[5]
Three-dimensional Mach-Zehnder interferometer in a microfluidic chip for spatially-resolved label-free detection [J].
Crespi, Andrea ;
Gu, Yu ;
Ngamsom, Bongkot ;
Hoekstra, Hugo J. W. M. ;
Dongre, Chaitanya ;
Pollnau, Markus ;
Ramponi, Roberta ;
van den Vlekkert, Hans H. ;
Watts, Paul ;
Cerullo, Giulio ;
Osellame, Roberto .
LAB ON A CHIP, 2010, 10 (09) :1167-1173
[6]
Loop-Mediated Isothermal Amplification Integrated on Microfluidic Chips for Point-of-Care Quantitative Detection of Pathogens [J].
Fang, Xueen ;
Liu, Yingyi ;
Kong, Jilie ;
Jiang, Xingyu .
ANALYTICAL CHEMISTRY, 2010, 82 (07) :3002-3006
[7]
Influence of different silica derivatives in the immobilization and stabilization of a Bacillus licheniformis protease (Subtilisin Carlsberg) [J].
Ferreira, L ;
Ramos, MA ;
Dordick, JS ;
Gil, MH .
JOURNAL OF MOLECULAR CATALYSIS B-ENZYMATIC, 2003, 21 (4-6) :189-199
[8]
Repositioning of cells by mechanotaxis on surfaces with micropatterned Young's modulus [J].
Gray, DS ;
Tien, J ;
Chen, CS .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2003, 66A (03) :605-614
[9]
ALKYLCHLOROSILANE REACTIONS AT THE SILICA SURFACE [J].
HAIR, ML ;
TRIPP, CP .
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 1995, 105 (01) :95-103
[10]
Crosslinked polydimethylsiloxane exposed to oxygen plasma studied by neutron reflectometry and other surface specific techniques [J].
Hillborg, H ;
Ankner, JF ;
Gedde, UW ;
Smith, GD ;
Yasuda, HK ;
Wikström, K .
POLYMER, 2000, 41 (18) :6851-6863