Plasma-polymerized films for biosensors

被引:97
作者
Muguruma, H [1 ]
Karube, I
机构
[1] Kochi Univ Technol, Dept Environm Syst Engn, Kochi 7828502, Japan
[2] Univ Tokyo, Adv Sci & Technol Res Ctr, Meguro Ku, Tokyo 1538904, Japan
关键词
plasma-polymerized film; immobilization matrix; biosensors;
D O I
10.1016/S0165-9936(98)00098-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A biosensor is a useful tool for chemical, biochemical, medical and environmental fields because of its compact size, real time analysis, nearly reagentless operation, simple pretreatment protocols and simplicity of use. The performance of the biosensor often depends on how well the biological components are combined to the transducers, which is also referred to as 'immobilization of biological components' or 'interfacial design'. A plasma-polymerized film, achieved in glow discharge or plasma in vapor phase, offers a new alternative for use in the interfacial design of the biosensors. The properties of the film are that they (i) are extremely thin (<1 mu m), (ii) provide good adhesion to the substrate, (iii) are pin-hole free and present a flat surface structure, (iv) are mechanically and chemically stable because of the highly branched and cross-linked structure in the polymer, and (v) allow for a large amount of biological components such as enzymes and antibodies to be loaded onto the surface of the film because of its biocompatible characteristics. The films have potential for use in the interfacial design for biosensors from both a fundamental and a practical aspect. In this article, we review the usefulness of plasma-polymerized films as interfaces in biosensing applications. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:62 / 68
页数:7
相关论文
共 27 条
[1]   STUDY OF PERFORMANCE AND CHEMICAL CHARACTERISTICS OF COMPOSITE REVERSE-OSMOSIS MEMBRANES PREPARED BY PLASMA POLYMERIZATION OF ALLYLAMINE [J].
BELL, AT ;
WYDEVEN, T ;
JOHNSON, CC .
JOURNAL OF APPLIED POLYMER SCIENCE, 1975, 19 (07) :1911-1930
[2]   Surface plasmon resonance multisensing [J].
Berger, CEH ;
Beumer, TAM ;
Kooyman, RPH ;
Greve, J .
ANALYTICAL CHEMISTRY, 1998, 70 (04) :703-706
[3]   BIOCHEMICAL ASPECTS OF BIOSENSORS [J].
BYFIELD, MP ;
ABUKNESHA, RA .
BIOSENSORS & BIOELECTRONICS, 1994, 9 (4-5) :373-400
[4]   CHEMICAL DERIVATIZATION IN ELECTRON-SPECTROSCOPY FOR CHEMICAL-ANALYSIS OF SURFACE FUNCTIONAL-GROUPS INTRODUCED ON LOW-DENSITY POLYETHYLENE FILM [J].
EVERHART, DS ;
REILLEY, CN .
ANALYTICAL CHEMISTRY, 1981, 53 (04) :665-676
[5]   SURFACE-PLASMON RESONANCE AND IMMUNOSENSORS [J].
FLANAGAN, MT ;
PANTELL, RH .
ELECTRONICS LETTERS, 1984, 20 (23) :968-970
[6]  
HIRATSUKA A, IN PRESS
[7]   ATTACHMENT OF AMINO GROUPS TO POLYMER SURFACES BY RADIOFREQUENCY PLASMAS [J].
HOLLAHAN, JR ;
STAFFORD, BB ;
FALB, RD ;
PAYNE, ST .
JOURNAL OF APPLIED POLYMER SCIENCE, 1969, 13 (04) :807-&
[8]  
KAMPFRATH G, 1989, ANAL LETT, V22, P2423
[9]   Microfabricated biosensors and microanalytical systems for blood analysis [J].
Lauks, IR .
ACCOUNTS OF CHEMICAL RESEARCH, 1998, 31 (05) :317-324
[10]   SURFACE-PLASMON RESONANCE FOR GAS-DETECTION AND BIOSENSING [J].
LIEDBERG, B ;
NYLANDER, C ;
LUNDSTROM, I .
SENSORS AND ACTUATORS, 1983, 4 (02) :299-304