Beam intensity modulation to reduce the field sizes for conformal irradiation of lung tumors: A dosimetric study

被引:28
作者
Brugmans, MJP [1 ]
van der Horst, A [1 ]
Lebesque, JV [1 ]
Mijnheer, BJ [1 ]
机构
[1] Netherlands Canc Inst, Antoni Van Leeuwenhoek Huis, Dept Radiotherapy, NL-1066 CX Amsterdam, Netherlands
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1999年 / 43卷 / 04期
关键词
lung cancer; intensity modulation; dosimetry; inhomogeneities; beam penumbra; target motion;
D O I
10.1016/S0360-3016(98)00489-1
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: In conformal radiotherapy of lung tumors, penumbra broadening in lung tissue necessitates the use of larger field sizes to achieve the same target coverage as in a homogeneous environment. In an idealized model configuration, some fundamental aspects of field size reduction were investigated, both for the static situation and for a moving tumor, while maintaining the dose homogeneity in the target volume by employing a simple beam-intensity modulation technique. Methods and Materials: An inhomogeneous phantom, consisting of polystyrene, cork, and polystyrene layers, with a 6 x 6 x 6 cm(3) polystyrene cube inside the cork representing the tumor, was used to simulate a lung cancer treatment. Film dosimetry experiments were performed for an AP-PA irradiation technique with 8-MV or 18-MV beams. Dose distributions were compared for large square fields, small square fields, and intensity-modulated fields in which additional segments increase the dose at the edge of the field. The effect of target motion was studied by measuring the dose distribution for the solid cube, displaced with respect to the beams. Results: For the 18-MV beam, the field sizes required to establish a sufficient target coverage are larger than for the 8-MV beam. For each beam energy, the mean dose in cork can significantly be reduced (at least a factor of 1.6) by decreasing the field size with 2 cm, while keeping the mean target dose constant. Target dose inhomogeneity for these smaller fields is limited if the additional edge segments are applied for 8% of the number of monitor units given with the open fields. The target dose distribution averaged over a motion cycle is hardly affected if the target edge does not approach the field edge to within 3 mm. Conclusions: For lung cancer treatment, a beam energy of 8 MV is more suitable than 18 MV. The mean lung dose can be significantly reduced by decreasing the field sizes of conformal fields. The smaller fields result in the same biological effect to the tumor if the mean target dose is kept constant. Intensity modulation can be employed to maintain the same target dose homogeneity for these smaller fields. As long as the target (with a 3 mm margin) stays within the field portal, application of a margin for target motion is not necessary, (C) 1999 Elsevier Science Inc.
引用
收藏
页码:893 / 904
页数:12
相关论文
共 32 条
  • [1] [Anonymous], 1993, 50 ICRU
  • [2] Promising survival with three-dimensional conformal radiation therapy for non-small cell lung cancer
    Armstrong, J
    Raben, A
    Zelefsky, M
    Burt, M
    Leibel, S
    Burman, C
    Kutcher, G
    Harrison, L
    Hahn, C
    Ginsberg, R
    Rusch, V
    Kris, M
    Fuks, Z
    [J]. RADIOTHERAPY AND ONCOLOGY, 1997, 44 (01) : 17 - 22
  • [3] 3-DIMENSIONAL CONFORMAL RADIATION-THERAPY MAY IMPROVE THE THERAPEUTIC RATIO OF HIGH-DOSE RADIATION-THERAPY FOR LUNG-CANCER
    ARMSTRONG, JG
    BURMAN, C
    LEIBEL, S
    FONTENLA, D
    KUTCHER, G
    ZELEFSKY, M
    FUKS, Z
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 26 (04): : 685 - 689
  • [4] OPTIMAL DOSE DISTRIBUTION FOR ERADICATION OF HETEROGENEOUS TUMORS
    BRAHME, A
    AGREN, AK
    [J]. ACTA ONCOLOGICA, 1987, 26 (05) : 377 - 385
  • [5] DOSIMETRIC PRECISION REQUIREMENTS IN RADIATION-THERAPY
    BRAHME, A
    [J]. ACTA RADIOLOGICA ONCOLOGY, 1984, 23 (05): : 379 - 391
  • [6] Brahme A., 1994, INT SEM EUR MIDDL E, P37
  • [7] BRUGMANS MJP, 1997, INT J RADIAT ONCOL, V41, P729
  • [8] FITTING OF NORMAL TISSUE TOLERANCE DATA TO AN ANALYTIC-FUNCTION
    BURMAN, C
    KUTCHER, GJ
    EMAMI, B
    GOITEIN, M
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (01): : 123 - 135
  • [9] Planning and delivering high doses to targets surrounding the spinal cord at the lower neck and upper mediastinal levels: Static beam-segmentation technique executed with a multileaf collimator
    DeNeve, W
    DeWagter, C
    DeJaeger, K
    Thienpont, M
    Colle, C
    Derycke, S
    Schelfhout, J
    [J]. RADIOTHERAPY AND ONCOLOGY, 1996, 40 (03) : 271 - 279
  • [10] Field margin reduction using intensity-modulated x-ray beams formed with a multileaf collimator
    Dirkx, MLP
    Heijmen, BJM
    Korevaar, GA
    vanOs, MJH
    Stroom, JC
    Koper, PCM
    Levendag, PC
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 38 (05): : 1123 - 1129