Measurement of radiation distribution on the absorber in an asymmetric CPC collector

被引:17
作者
Adsten, M
Hellström, B
Karlsson, B [1 ]
机构
[1] Vattenfall Utveckling AB, S-81426 Alvkarleby, Sweden
[2] Lund Univ, Inst Technol, Dept Construct & Architecture, S-22100 Lund, Sweden
[3] Univ Uppsala, Angstom Lab, S-75121 Uppsala, Sweden
关键词
D O I
10.1016/j.solener.2003.08.024
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 [动力工程及工程热物理]; 0820 [石油与天然气工程];
摘要
A method to estimate the annual collected energy and the annual average optical efficiency factor is suggested. The radiation distribution on the absorber of an asymmetric CPC collector with a flat bi-facial absorber is measured for three different absorber mounting angles using a photo diode. The annual optical efficiency factors and a relative measure of the annual collected energy are determined for collectors with the absorber fin thickness 0.5 and 1 mm, and for a collector with a teflon convection suppression film mounted around the absorber. With the local optical efficiency factors and the annual incident solar energy distribution considered, the analysis indicates that the energy gain for a mounting angle of 20 is higher than for a collector with 65 absorber mounting angle. The annual collected energy is increased with 6-8% if the absorber fin thickness is increased from 0.5 to 1 mm. The annual average optical efficiency factor is relatively independent of the absorber mounting angle. It was found to be 0.87-0.88 for a collector with a 0.5 mm thick absorber fin and 0.92 for a collector with a 1 mm thick absorber fin or for a collector with 0.5 mm thick absorber fin with a teflon convection suppression film added. The low annual average optical efficiency factor is not caused by the uneven irradiance distribution but by the relatively high U-L-values. (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:199 / 206
页数:8
相关论文
共 11 条
[1]
ADSTEN M, 2002, THESIS FACULTY SCI T
[2]
ADSTEN M, IN PRESS SOLAR ENERG
[3]
New nonimaging static concentrators for bifacial photovoltaic solar cells [J].
Benítez, P ;
Hernández, M ;
Mohedano, R ;
Miñano, JC ;
Muñoz, F .
NONIMAGING OPTICS: MAXIMUM EFFICIENCY LIGHT TRANSFER V, 1999, 3781 :22-29
[4]
DUFFIE JA, 1991, SOLAR ENG THERMAL PR, P346
[5]
FEND T, 1999, J PHYS 4
[6]
HELLSTROM B, 2001, 0122 VATT UTV
[7]
KARLSSON B, 2000, P EUR 2000 COP DEN J
[8]
Irradiation distribution diagrams and their use for estimating collectable energy [J].
Ronnelid, M ;
Karlsson, B .
SOLAR ENERGY, 1997, 61 (03) :191-201
[9]
An experimental procedure to determine solar energy flux distributions on the absorber of line-axis compound parabolic concentrators [J].
Smyth, M ;
Zacharopoulos, A ;
Eames, PC ;
Norton, B .
RENEWABLE ENERGY, 1999, 16 (1-4) :761-764
[10]
Industrially sputtered solar absorber surface [J].
Wackelgard, E ;
Hultmark, G .
SOLAR ENERGY MATERIALS AND SOLAR CELLS, 1998, 54 (1-4) :165-170