Multivariate optimization of a solid-phase microextraction method for the analysis of phthalate esters in environmental waters

被引:153
作者
Polo, M [1 ]
Llompart, M [1 ]
Garcia-Jares, C [1 ]
Cela, R [1 ]
机构
[1] Univ Santiago de Compostela, Inst Invest & Anal Alimentario, Fac Quim, Dept Quim Analit Nutr & Bromatol, E-15782 Santiago De Compostela, Spain
关键词
multifactor optimization; factorial design; solid-phase microextraction; extraction methods; phthalate esters; water analysis;
D O I
10.1016/j.chroma.2004.12.040
中图分类号
Q5 [生物化学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
A solid-phase microextraction method (SPME) coupled to gas chromatography-mass spectrometry (GC-MS) has been developed for the determination of the six phthalate esters included in the US Environmental Protection Agency (EPA) Priority Pollutants list in water samples. These compounds are dimethyl phthalate (DMP), diethyl phthalate (DEP), di-n-butyl phthalate (DBP), butylbenzyl phthalate (BBP), di-2-ethylhexyl phthalate (DEHP) and di-n-octyl phthalate (DOP). Detailed discussion of the different parameters, which could affect the extraction process, is presented. Main factors have been studied and optimized by means of a multifactor categorical design. Different commercial fibers, polydimethylsiloxane (PDMS), polydimethylsiloxane-divinylbenzene (PDMS-DVB), polyacrylate (PA), Carboxen-polydimethylsiloxane (CAR-PDMS) and Carbowax-divinylbenzene (CW-DVB), have been investigated, as well as the extraction mode, exposing the fiber directly into the sample (DSPME) or into the headspace over the sample (HS-SPME), and different extraction temperatures. The use of this experimental design allowed for the evaluation of interactions between factors. Extraction kinetics has also been studied. The optimized microextraction method showed linear response and good precision for all target analytes. Detection limits were estimated considering the contamination problems associated to phthalate analysis. They were in the low pg mL(-1), excluding DEHP (100 pg mL(-1)). The applicability of the developed SPME method was demonstrated for several real water samples including mineral, river, industrial port and sewage water samples. All the target analytes were found in real samples. Levels of DEP and DEHP were over 1 ng mL(-1) in some of the samples. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:63 / 72
页数:10
相关论文
共 30 条
[1]
Alpendurada MD, 2000, J CHROMATOGR A, V889, P3
[2]
[Anonymous], 2001, OFFICIAL J EUROPEA L, V15, P1
[3]
[Anonymous], 1999, INTR WAT POL STAND
[4]
*COMM COUNC EUR PA, 2001, COM2001262
[5]
*COMM COUNC EUR PA, 2001, COM1999706
[6]
MultiSimplex optimisation of the solid-phase microextraction-gas chromatographic-mass spectrometric determination of polycyclic aromatic hydrocarbons, polychlorinated biphenyls and phthalates from water samples [J].
Cortazar, E ;
Zuloaga, O ;
Sanz, J ;
Raposo, JC ;
Etxebarria, N ;
Fernández, LA .
JOURNAL OF CHROMATOGRAPHY A, 2002, 978 (1-2) :165-175
[7]
Cousins IT, 2003, HANDB ENVIRON CHEM, V3, P57
[8]
Danish Environmental Protection Agency, 2002, GUID REM CONT SIT
[9]
David F, 2003, HANDB ENVIRON CHEM, V3, P9
[10]
Phthalate esters detected in various water samples and biodegradation of the phthalates by microbes isolated from river water [J].
Hashizume, K ;
Nanya, J ;
Toda, C ;
Yasui, T ;
Nagano, H ;
Kojima, N .
BIOLOGICAL & PHARMACEUTICAL BULLETIN, 2002, 25 (02) :209-214