Certified reference materials (GBW09170 and 09171) of creatinine in human serum

被引:9
作者
Dai, Xinhua [1 ]
Fang, Xiang [1 ]
Shao, Mingwu [1 ]
Li, Ming [1 ]
Huang, Zejian [1 ]
Li, Hongmei [1 ]
Jiang, You [1 ]
Song, Dewei [1 ]
He, Yajuan [1 ]
机构
[1] Natl Inst Metrol, Beijing 100013, Peoples R China
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2011年 / 879卷 / 5-6期
关键词
Creatinine; Certified reference materials (CRMs); Liquid chromatography (LC); Isotope dilution (ID); Mass spectrometry (MS); Human serum; MASS-SPECTROMETRY; ASSAY;
D O I
10.1016/j.jchromb.2010.12.031
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Creatinine is the most widely used clinical marker for assessing renal function. Concentrations of creatinine in human serum need to be carefully checked in order to ensure accurate diagnosis of renal function. Therefore, development of certified reference materials (CRMs) of creatinine in serum is of increasing importance. In this study, two new CRMs (Nos. GBW09170 and 09171) for creatinine in human serum have been developed. They were prepared with mixtures of several dozens of healthy people's and kidney disease patient's serum, respectively. The certified values of 8.10, 34.1 mg/kg for these two CRMs have been assigned by liquid chromatography-isotope dilution mass spectrometry (LC-IDMS) method which was validated by using standard reference material (SRM) of SRM909b (a reference material obtained from National Institute of Standards and Technology, NIST). The expanded uncertainties of certified values for low and high concentrations were estimated to be 1.2 and 1.1%, respectively. The certified values were further confirmed by an international intercomparison for the determination of creatinine in human serum (Consultative Committee for Amount of Substance, CCQM) of K80 (CCQM-K80). These new CRMs of creatinine in human serum pool are totally native without additional creatinine spiked for enrichment. These new CRMs are capable of validating routine clinical methods for ensuring accuracy, reliability and comparability of analytical results from different clinical laboratories. They can also be used for instrument validation, development of secondary reference materials, and evaluating the accuracy of high order clinical methods for the determination of creatinine in human serum. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:429 / 435
页数:7
相关论文
共 18 条
[1]  
[Anonymous], CERT AN STAND REF MA
[2]   Preparation of creatinine standard stock solution [J].
Dai, Xinhua .
ANALYTICAL LETTERS, 2007, 40 (15) :2946-2948
[3]   Application of Liquid Chromatography/LTQ Linear Ion Trap Mass Spectrometry for Quantifying the Biomarkers Creatinine and Cortisol in Serum [J].
Dai, Xinhua ;
Fang, Xiang ;
Yang, Mengrui ;
Li, Hongmei ;
He, Yajuan .
ANALYTICAL LETTERS, 2008, 41 (16) :2912-2922
[4]  
FOSSATI P, 1983, CLIN CHEM, V29, P1494
[5]  
GUDER WG, 1986, J CLIN CHEM CLIN BIO, V24, P889
[6]  
GUM, 2008, EV MEAS DAT GUID EXP
[7]   A COMPARISON OF METHODS FOR CREATININE DETERMINATION [J].
HENKEL, E ;
KOKENGE, A ;
MEIER, H .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1980, 301 (02) :175-177
[8]  
*JOINT COMM TRAC L, 2006, DAT HIGH ORD REF MAT
[9]  
NARAYANAN S, 1980, CLIN CHEM, V26, P1119
[10]  
OSBERG IM, 1978, CLIN CHEM, V24, P1196