On-chip proteolytic digestion and analysis using "wrong-way-round" electrospray time-of-flight mass spectrometry

被引:96
作者
Lazar, IM [1 ]
Ramsey, RS [1 ]
Ramsey, JM [1 ]
机构
[1] Oak Ridge Natl Lab, Div Chem & Analyt Sci, Oak Ridge, TN 37831 USA
关键词
D O I
10.1021/ac001420+
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Rapid protein digestion and analysis using a hybrid microchip nanoelectrospray device and time-of-flight mass spectrometry detection are reported. The device consists of a planar glass chip with microfabricated channels coupled to a disposable nanospray emitter. Reactions between substrate and enzyme (trypsin), mixed off-chip and then immediately loaded into a sample reservoir on the device, are monitored in real time following the onset of electrospray, Protein cleavage products are determined at the optimum pH for generating tryptic fragments, directly from the digestion buffer using "wrong-way-round" electrospray, i.e., monitoring (MH)(+) ions from basic solutions. Intense tryptic peptide ions are observed within a few minutes following sample loading on the microchip. Proteins were identified from low femtomole or even attomole quantities of analyte/spectrum using peptide mass fingerprinting, loading 0.1-2 pmol/muL of sample on the chip. The sequence coverage for analyzed proteins ranged from 70 to 95%. The rapid analysis of human hemoglobin is demonstrated using the technique.
引用
收藏
页码:1733 / 1739
页数:7
相关论文
共 59 条
[1]  
[Anonymous], 1997, FUNDAMENTALS CLIN HE
[2]   Microfluidic devises connected to fused-silica capillaries with minimal dead volume [J].
Bings, NH ;
Wang, C ;
Skinner, CD ;
Colyer, CL ;
Thibault, P ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 1999, 71 (15) :3292-3296
[3]  
Blackburn RK, 1997, J AM SOC MASS SPECTR, V8, P483
[4]  
Cao P, 1998, RAPID COMMUN MASS SP, V12, P864, DOI 10.1002/(SICI)1097-0231(19980715)12:13<864::AID-RCM244>3.0.CO
[5]  
2-G
[6]  
Chen YJ, 1998, RAPID COMMUN MASS SP, V12, P1994, DOI 10.1002/(SICI)1097-0231(19981230)12:24<1994::AID-RCM423>3.0.CO
[7]  
2-2
[8]   Variable flow liquid chromatography tandem mass spectrometry and the comprehensive analysis of complex protein digest mixtures [J].
Davis, MT ;
Lee, TD .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1997, 8 (10) :1059-1069
[9]   Rapid protein identification using a microscale electrospray LC/MS system on an ion trap mass spectrometer [J].
Davis, MT ;
Lee, TD .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1998, 9 (03) :194-201
[10]  
Figeys D, 1998, RAPID COMMUN MASS SP, V12, P1435, DOI 10.1002/(SICI)1097-0231(19981030)12:20<1435::AID-RCM349>3.3.CO