Comparison of universal detectors for high-temperature micro liquid chromatography

被引:42
作者
Hazotte, A. [1 ]
Libong, D. [1 ]
Matoga, A. [1 ]
Chaminade, P. [1 ]
机构
[1] Univ Paris Sud, Sch Pharm, Grp Chim Analyt Paris Sud, IFR 141, F-92296 Chatenay Malabry, France
关键词
high-temperature liquid chromatography; micro column liquid chromatography; charged aerosol detection; evaporative light-scattering detection; mass spectrometry; APCI; ESI; lipids;
D O I
10.1016/j.chroma.2007.09.008
中图分类号
Q5 [生物化学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
This study compares, through micro high-temperature liquid chromatography (mu HTLC, three commercial universal detectors that allow a direct detection of lipids. The detectors are: the charged aerosol detector (CAD), the evaporative light-scattering detector (ELSD) and the ion trap mass spectrometer with atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI) sources (APCI-MS and ESI-MS). This study shows the feasibility to use the high temperature with these detectors and hybrid behavior between concentration and mass flow rate detector in mu HTLC. The detectors were compared in terms of response intensity, linearity and limit of detection for different high temperatures. The charged aerosol detector shows a linear response from 5 to 500 mu g/mL and the correlation coefficients (r(2)) obtained for squalene, cholesterol and ceramide IIIB exceed 0.99. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:52 / 61
页数:10
相关论文
共 30 条
[1]
Temperature-programmed packed capillary liquid chromatography coupled to evaporative light-scattering detection and electrospray ionization time-of-flight mass spectrometry for characterization of high-molecular-mass hindered amine light stabilizers [J].
Andersen, T ;
Skuland, IL ;
Holm, A ;
Trones, R ;
Greibrokk, T .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1029 (1-2) :49-56
[2]
ANDERSSON MBO, 1998, J MICROCOLUMN SEP, P249
[3]
Corona-charged aerosol detection in supercritical fluid chromatography for pharmaceutical analysis [J].
Brunelli, C. ;
Gorecki, T. ;
Zhao, Y. ;
Sandra, P. .
ANALYTICAL CHEMISTRY, 2007, 79 (06) :2472-2482
[4]
Byrdwell W.C., 1997, NEW TECH APPL LIPID, P45
[5]
EVAPORATIVE ANALYZER AS A MASS DETECTOR FOR LIQUID-CHROMATOGRAPHY [J].
CHARLESWORTH, JM .
ANALYTICAL CHEMISTRY, 1978, 50 (11) :1414-1420
[6]
CHRISTIE WW, 1985, J LIPID RES, V26, P507
[7]
Christie WW, 1998, ANALUSIS, V26, pM34, DOI 10.1051/analusis:199826030034
[8]
COBB Z, 2001, J MICROCOLUMN SEP, P169
[9]
Atmospheric pressure photoionization coupled to porous graphitic carbon liquid chromatography for the analysis of globotriaosylceramides.: Application to Fabry disease [J].
Delobel, A ;
Roy, S ;
Touboul, D ;
Gaudin, K ;
Germain, DP ;
Baillet, A ;
Brion, F ;
Prognon, P ;
Chaminade, P ;
Laprévote, O .
JOURNAL OF MASS SPECTROMETRY, 2006, 41 (01) :50-58
[10]
Development and testing of a detection method for liquid chromatography based on aerosol charging [J].
Dixon, RW ;
Peterson, DS .
ANALYTICAL CHEMISTRY, 2002, 74 (13) :2930-2937