Clinical utility of external immunoscintigraphy with the IMMU-4 technetium-99m fab' antibody fragment in patients undergoing surgery for carcinoma of the colon and rectum: Results of a pivotal, phase III trial

被引:114
作者
Moffat, FL
Pinsky, CM
Hammershaimb, L
Petrelli, NJ
Patt, YZ
Whaley, FS
Goldenberg, DM
机构
[1] CTR MOL MED & IMMUNOL, GARDEN STATE CANC CTR, NEWARK, NJ 07103 USA
[2] UNIV MIAMI, SCH MED, DEPT SURG, MIAMI, FL USA
[3] IMMUNOMEDICS INC, MORRIS PLAINS, NJ USA
[4] ROSWELL PK CANC CTR, DEPT SURG ONCOL & ENDOSCOPY, BUFFALO, NY USA
[5] MD ANDERSON HOSP & TUMOR INST, DEPT GASTROINTESTINAL MED ONCOL & DIGEST DIS, DIV MED, HOUSTON, TX USA
[6] PHARM INC, COLUMBUS, OH USA
关键词
D O I
10.1200/JCO.1996.14.8.2295
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To assess the performance and the potential clinical impact of a new antibody imaging agent, CPA-Scan (Immunomedics Inc, Morris Plains, NJ), in 210 presurgical patients with advanced recurrent or metastatic colorectal carcinomas. Methods: CEA-Scan, an anti-carcinoembryonic antigen (CEA) Fab' antibody fragment labeled with technetium-99m-pertechnetate (Tc-99m), was injected intravenously (IV), and external scintigraphy was performed 2 to 5 and 18 to 24 hours later. Imaging with conventional diagnostic modalities (CDM) was also performed, and findings were confirmed by surgery and histology. Results: The sensitivity of CEA-Scan was superior to that of CDM in the extrahepatic abdomen (55% v32%; P=.007) and pelvis (69% v48%; P=.005), and CEA-Scan findings complemented those of CDM in the liver. Among 122 patients with known disease, the positive predictive value was significantly higher when both modalities were positive (98%) compared with each alone (68% to 70%), potentially obviating the need for histologic confirmation when both tests are positive. Imaging accuracy also was significantly improved by adding CPA-Scan to CDM. In 88 patients with occult cancer, imaging accuracy was enhanced significantly by CEA-Scan combined with CDM (61% v 33%). Potential clinical benefit from CEA-Scan was demonstrated in 89 of 210 patients. Only two patients developed human anti-mouse antibodies (HAMA) to CPA-Scan after a single injection, and none of 19 assessable patients after two injections. Conclusion: CEA-Scan affords high-quality, same-day imaging, uses an inexpensive and readily available raodionuclide, adds clinically significant information in assessing extent and location of disease in colorectal cancer patients,. and only rarely induces a HAMA response. (C) 1996 by American Society of Clinical Oncology.
引用
收藏
页码:2295 / 2305
页数:11
相关论文
共 57 条
[1]  
Abdel-Nabi H, 1992, Semin Urol, V10, P45
[2]   IN-111 LABELED MONOCLONAL-ANTIBODY IMMUNOSCINTIGRAPHY IN COLORECTAL-CARCINOMA - SAFETY, SENSITIVITY, AND PRELIMINARY CLINICAL-RESULTS [J].
ABDELNABI, H ;
DOERR, RJ ;
CHAN, HW ;
BALU, D ;
SCHMELTER, RF ;
MAGUIRE, RT .
RADIOLOGY, 1990, 175 (01) :163-171
[3]  
ABDELNABI H, 1992, DIAGNOSIS COLORECTAL, P73
[4]  
ABDELNABI H, 1992, AM J SURG, V163, P448
[5]   SCINTIGRAPHIC DETECTION OF GASTRIC AND PANCREATIC CARCINOMAS WITH IN-111 ZCE 025 MONOCLONAL-ANTIBODY [J].
ABDELNABI, HH ;
SCHWARTZ, AN ;
WECHTER, DG ;
HIGANO, CS ;
ORTMANNABI, JA ;
UNGER, MW .
WORLD JOURNAL OF SURGERY, 1991, 15 (01) :122-127
[6]  
[Anonymous], PRACTICAL NONPARAMET
[7]   TESTS FOR LINEAR TRENDS IN PROPORTIONS AND FREQUENCIES [J].
ARMITAGE, P .
BIOMETRICS, 1955, 11 (03) :375-386
[8]  
ATHANASSIOU A, 1988, INT J CANCER, P89
[9]   CLINICAL PERSPECTIVE OF HUMAN COLORECTAL-CANCER METASTASIS [J].
AUGUST, DA ;
OTTOW, RT ;
SUGARBAKER, PH .
CANCER AND METASTASIS REVIEWS, 1984, 3 (04) :303-324
[10]   IMPACT OF RADIOLABELED ANTIBODY IMAGING ON MANAGEMENT OF COLON CANCER [J].
BEATTY, JD ;
HYAMS, DM ;
MORTON, BA ;
BEATTY, BG ;
WILLIAMS, LE ;
YAMAUCHI, D ;
MERCHANT, B ;
PAXTON, RJ ;
SHIVELY, JE .
AMERICAN JOURNAL OF SURGERY, 1989, 157 (01) :13-19