Controlled comparison of BacT/ALERT FAN aerobic medium and BACTEC fungal blood culture medium for detection of fungemia

被引:29
作者
McDonald, LC
Weinstein, MP
Fune, J
Mirrett, S
Reimer, LG
Reller, LB
机构
[1] Duke Univ, Med Ctr, Clin Microbiol Lab, Durham, NC 27710 USA
[2] Duke Univ, Sch Med, Dept Pathol, Durham, NC 27710 USA
[3] Duke Univ, Sch Med, Dept Med, Durham, NC 27710 USA
[4] Univ Med & Dent New Jersey, Robert Wood Johnson Med Sch, Robert Wood Johnson Univ Hosp, Microbiol Lab, New Brunswick, NJ 08901 USA
[5] Univ Med & Dent New Jersey, Robert Wood Johnson Med Sch, Dept Med, New Brunswick, NJ 08901 USA
[6] Univ Med & Dent New Jersey, Robert Wood Johnson Med Sch, Dept Pathol, New Brunswick, NJ 08901 USA
[7] Vet Affairs Med Ctr, Dept Pathol, Salt Lake City, UT 84148 USA
关键词
D O I
10.1128/JCM.39.2.622-624.2001
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Yeasts are an increasingly common cause of nosocomial bloodstream infections, Methods for their detection are many; controlled comparisons are few. The vented FAN aerobic blood culture medium has been shown to be superior to the standard BacT/ALERT aerobic medium for the detection of fungemia as well as bacteremia. The BACTEC selective fungal medium (FM) (BD Biosciences, Sparks, Md,) allowed detection of more episodes of fungemia than did a resin-containing medium with equal volumes of blood cultured, Therefore, we compared vented FAN to FM for the ability to recover fungi from the blood of patients who were at increased risk of having fungemia, From 5,109 cultures processed for which both FAN and FM battles were adequately filled, fungi were recovered from 87 cultures. Of these, 47 were detected with both bottles, 12 were detected with FAN only, and 28 were detected with FM only (P < 0.05). FAN was the first bottle positive for 36 of the 47 cultures for which both bottles yielded the same fungus, whereas the FM bottle was the first bottle positive for 11 cultures (P < 0.001), A total of 54 episodes of fungemia were identified, with 40 detected by both media, 4 detected only by FAN, and 10 detected only by FM (P value, not significant). We conclude that the vented FAN aerobic bottle is comparable to the FM bottle for detection of episodes of yeast infection but has the added benefit of detecting bacteria.
引用
收藏
页码:622 / 624
页数:3
相关论文
共 13 条
  • [1] CANDIDEMIA IN A TERTIARY CARE HOSPITAL - EPIDEMIOLOGY, RISK-FACTORS, AND PREDICTORS OF MORTALITY
    FRASER, VJ
    JONES, M
    DUNKEL, J
    STORFER, S
    MEDOFF, G
    DUNAGAN, WC
    [J]. CLINICAL INFECTIOUS DISEASES, 1992, 15 (03) : 414 - 421
  • [2] LABORATORY DETECTION OF FUNGEMIA
    GEHA, DJ
    ROBERTS, GD
    [J]. CLINICS IN LABORATORY MEDICINE, 1994, 14 (01) : 83 - 97
  • [3] MICROBIOLOGICAL AND CLINICAL-EVALUATION OF THE ISOLATOR LYSIS-CENTRIFUGATION BLOOD CULTURE TUBE
    HENRY, NK
    MCLIMANS, CA
    WRIGHT, AJ
    THOMPSON, RL
    WILSON, WR
    WASHINGTON, JA
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1983, 17 (05) : 864 - 869
  • [4] DETECTION OF FUNGEMIA OBSCURED BY CONCOMITANT BACTEREMIA - INVITRO AND INVIVO STUDIES
    HOCKEY, LJ
    FUJITA, NK
    GIBSON, TR
    ROTROSEN, D
    MONTGOMERIE, JZ
    EDWARDS, JE
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1982, 16 (06) : 1080 - 1085
  • [5] Controlled clinical laboratory comparison of BACTEC plus aerobic/F resin medium with BacT/Alert aerobic FAN medium for detection of bacteremia and fungemia
    Jorgensen, JH
    Mirrett, S
    McDonald, LC
    Murray, PR
    Weinstein, MP
    Fune, J
    Trippy, CW
    Masterson, M
    Reller, LB
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (01) : 53 - 58
  • [6] MCNEMAR Q, 1962, PSYCHOL STATISTICS, P209
  • [7] Murray P.R., 1999, MANUAL CLIN MICROBIO, V7th
  • [8] Comparison of isolator 1.5 and BACTEC NR660 aerobic 6A blood culture systems for detection of fungemia in children
    Petti, CA
    Zaidi, AKM
    Mirrett, S
    Reller, LB
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1996, 34 (08) : 1877 - 1879
  • [9] NOSOCOMIAL BLOOD-STREAM INFECTION IN CRITICALLY ILL PATIENTS - EXCESS LENGTH OF STAY, EXTRA COSTS, AND ATTRIBUTABLE MORTALITY
    PITTET, D
    TARARA, D
    WENZEL, RP
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1994, 271 (20): : 1598 - 1601
  • [10] CONTROLLED EVALUATION OF BACT ALERT STANDARD AEROBIC AND FAN AEROBIC BLOOD CULTURE BOTTLES FOR DETECTION OF BACTEREMIA AND FUNGEMIA
    WEINSTEIN, MP
    MIRRETT, S
    REIMER, LG
    WILSON, ML
    SMITHELEKES, S
    CHUARD, CR
    JOHO, KL
    RELLER, LB
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (04) : 978 - 981