Single chain entanglement: A Monte Carlo simulation of dilute solution capillary electrophoresis

被引:25
作者
Starkweather, ME
Muthukumar, M [1 ]
Hoagland, DA
机构
[1] Univ Massachusetts, Dept Polymer Sci & Engn, Amherst, MA 01003 USA
[2] Univ Massachusetts, Mat Res Sci & Engn Ctr, Amherst, MA 01003 USA
关键词
D O I
10.1021/ma971651r
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
The configurational interactions of a single flexible polyelectrolyte probe chain driven at moderate electric field through a single neutral frozen host chain are investigated using the Monte Carlo simulation method. The simulated probe length varies from 25 to 200 Kuhn steps, while the host length remains fixed at 200 Kuhn steps; the probe's charge density and the medium's Debye-Huckel screening length constitute additional parameters. The simulations reveal a strong and chain length dependent entanglement coupling between probe and host, consistent with recent experiments demonstrating that polyelectrolytes can be electrophoretically separated by molecular weight in a dilute solution of neutral polymers. Additionally, charge density and Debye-Huckel screening length are shown to be important factors in the separation mechanism, affecting both the probability of coupling and the duration of resulting entanglements. The scaling exponent relating entanglement time to molecular weight lies between the values of 2 and 3, the respective limits for Rouse and reptation disentanglement dynamics.
引用
收藏
页码:5495 / 5501
页数:7
相关论文
共 45 条
[1]   MOBILITY MODELS FOR STIFF AND FLEXIBLE MACROMOLECULES IN DILUTE GELS [J].
ARVANITIDOU, E ;
HOAGLAND, D ;
SMISEK, D .
BIOPOLYMERS, 1991, 31 (04) :435-447
[2]   HIGH-RESOLUTION SEPARATION OF DNA RESTRICTION FRAGMENTS BY CAPILLARY ELECTROPHORESIS IN CELLULOSE DERIVATIVE SOLUTIONS [J].
BABA, Y ;
ISHIMARU, N ;
SAMATA, K ;
TSUHAKO, M .
JOURNAL OF CHROMATOGRAPHY A, 1993, 653 (02) :329-335
[3]   CAPILLARY ELECTROPHORESIS OF DNA IN UNCROSS-LINKED POLYMER-SOLUTIONS [J].
BARRON, AE ;
SOANE, DS ;
BLANCH, HW .
JOURNAL OF CHROMATOGRAPHY A, 1993, 652 (01) :3-16
[4]   A TRANSIENT ENTANGLEMENT COUPLING MECHANISM FOR DNA SEPARATION BY CAPILLARY ELECTROPHORESIS IN ULTRADILUTE POLYMER-SOLUTIONS [J].
BARRON, AE ;
BLANCH, HW ;
SOANE, DS .
ELECTROPHORESIS, 1994, 15 (05) :597-615
[5]  
Barron AE, 1996, BIOTECHNOL BIOENG, V52, P259, DOI 10.1002/(SICI)1097-0290(19961020)52:2<259::AID-BIT7>3.3.CO
[6]  
2-#
[7]   MONTE-CARLO SIMULATION OF DNA ELECTROPHORESIS [J].
BATOULIS, J ;
PISTOOR, N ;
KREMER, K ;
FRISCH, HL .
ELECTROPHORESIS, 1989, 10 (5-6) :442-446
[8]   CAPILLARY ELECTROPHORESIS OF DNA IN AGAROSE SOLUTIONS AT 40-DEGREES-C [J].
BOCEK, P ;
CHRAMBACH, A .
ELECTROPHORESIS, 1991, 12 (12) :1059-1061
[9]   DANCING DNA IN CAPILLARY SOLUTION ELECTROPHORESIS [J].
CARLSSON, C ;
LARSSON, A ;
JONSSON, M ;
NORDEN, B .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1995, 117 (13) :3871-3872
[10]   POLY(ETHYLENEOXIDE) FOR HIGH-RESOLUTION AND HIGH-SPEED SEPARATION OF DNA BY CAPILLARY ELECTROPHORESIS [J].
CHANG, HT ;
YEUNG, ES .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1995, 669 (01) :113-123