Preparative application of commercial automated gel electrophoresis apparatus to subcellular-sized particles: Sequential isolations, fractions re-run, sodium dodecyl sulfate-polyacrylamide gel electrophoresis analysis, yield and purity

被引:5
作者
Chen, N [1 ]
Chrambach, A [1 ]
机构
[1] NICHHD, Macromol Anal Sect, Lab Cellular & Mol Biophys, NIH, Bethesda, MD 20892 USA
关键词
microsome; subcellular-sized particle; particle sieving; resolution; sieving media; agarose; laterally aggregated polyacrylamide; electroelution; yield; purity;
D O I
10.1002/elps.1150191810
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The analytical and preparative potential of automated gel electrophoresis apparatus with intermittent fluorescence scanning of the mi,oration path, the HPGE-1000 apparatus (LabIntelligence, Belmont, CA) was further developed in application to subcellular-sized particles. Resolution between two rat liver microsome components in agarose (MetaPhor) gel electrophoresis was found to increase with decreasing agarose concentration to 0.04%. It was less, even in an agarose solution at that low concentration, than that in laterally aggregated 4% polyacrylamide gel. The three components of the microsomal preparation were sequentially isolated from 0.6 and 0.8% agarose gel electropherograms. One fraction when reelectrophoresed was found to exhibit the original mobility and did not give rise to the other components. Yields of each component were near-quantitative after one or two electroelution steps. Based on protein content, no impurities could be detected in two of the microsome fractions; the third fraction contained 2% of nonmicrosome impurity. Sodium dodecyl sulfate-polyacrylamide gel electrophore sis (SDS-PAGE) patterns of all three microsome fractions were indistinguishable from one another and from that of the unfractionated microsome preparation.
引用
收藏
页码:3096 / 3102
页数:7
相关论文
共 20 条
[1]  
ALDROUBI A, 1995, APPL THEOR ELECTROPH, V5, P31
[2]   RECYCLING ISOELECTRIC-FOCUSING AND ISOTACHOPHORESIS [J].
BIER, M ;
TWITTY, GE ;
SLOAN, JE .
JOURNAL OF CHROMATOGRAPHY, 1989, 470 (02) :369-376
[3]   Separation and isolation of subcellular-sized particles by electrophoresis in polymer solution using the commercial scanning apparatus [J].
Chang, HT ;
Zakharov, SF ;
Chrambach, A .
ELECTROPHORESIS, 1996, 17 (04) :776-780
[4]   Preparative electrophoresis in a concentrated polymer solution: Automated procedure for microsome isolation [J].
Chang, HT ;
Chen, N ;
Sullivan, JV ;
Chrambach, A .
ANALYTICAL BIOCHEMISTRY, 1997, 247 (01) :111-114
[5]   HORIZONTAL GEL-ELECTROPHORESIS WITH SAMPLE VOLUMES UP TO 1.5 ML, USING A DISCONTINUOUS BUFFER SYSTEM AND AUTOMATED APPARATUS [J].
CHANG, HT ;
CHRAMBACH, A .
ELECTROPHORESIS, 1995, 16 (06) :952-957
[6]   Separation and microgram-scale isolation of sea urchin egg granules by electrophoresis in polyvinylpyrrolidone solution, using horizontal gel electrophoresis apparatus with fluorescence detector [J].
Chen, N ;
Radko, SP ;
Chrambach, A .
ELECTROPHORESIS, 1998, 19 (07) :1195-1204
[7]   Enhanced field strength and resolution in gel electrophoresis upon substitution of buffer by histidine at its isoelectric point [J].
Chen, N ;
Chrambach, A .
ELECTROPHORESIS, 1996, 17 (04) :699-703
[8]   Application of the commercial gel electrophoresis apparatus with intermittent fluorescence scanning to a nonfluorescing protein [J].
Chen, N ;
Chrambach, A .
ANALYTICAL BIOCHEMISTRY, 1996, 242 (01) :64-67
[9]   Quantitative and automated electrophoresis in sieving media [J].
Chrambach, A .
ELECTROPHORESIS, 1996, 17 (03) :454-464
[10]  
Chrambach A, 1985, PRACTICE QUANTITATIV, P1