Significant precision improvement for temperature mapping

被引:6
作者
Li, L [1 ]
Shapiro, EM
Leigh, JS
机构
[1] Univ Penn, MMRRCC, Dept Radiol, Stellar Chance Labs 6100, Philadelphia, PA 19104 USA
[2] Univ Penn, MMRRCC, Dept Chem, Philadelphia, PA 19104 USA
关键词
temperature mapping; precision improvement; Laplace; spherical mean value; RF heating;
D O I
10.1002/mrm.1245
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
MR temperature measurements are important for applications such as the evaluation of thermal therapies and radiofrequency (RF) coil heating effects. In this work the spherical mean value (SMV) method has been applied to significantly improve the precision of MR temperature mapping in a homogeneous gel phantom. Temperature-increase maps of the phantom were obtained with three-dimensional (3D) MR phase difference mapping after heating with the RIF coil. The temperature-increase distribution in most regions in the phantom is a harmonic function with the mean value property. Based on this property, the precision of temperature-increase maps was improved up to sixfold with the SMV method. Comparison of this method with conventional smoothing, further precision improvement, and the in vivo application of the SMV method are discussed. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:678 / 682
页数:5
相关论文
共 10 条
  • [1] AXLER S, 1992, HARMONIC FUNCTION TH
  • [2] CHURCHILL RV, 1984, COMPLEX VARIABLES AP, P233
  • [3] MAGNETIC RESONANCE-GUIDED THERMAL SURGERY
    CLINE, HE
    SCHENCK, JF
    WATKINS, RD
    HYNYNEN, K
    JOLESZ, FA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (01) : 98 - 106
  • [4] PRECISE AND FAST TEMPERATURE MAPPING USING WATER PROTON CHEMICAL-SHIFT
    ISHIHARA, Y
    CALDERON, A
    WATANABE, H
    OKAMOTO, K
    SUZUKI, Y
    KURODA, K
    SUZUKI, Y
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (06) : 814 - 823
  • [5] Calibration of water proton chemical shift with temperature for noninvasive temperature imaging during focused ultrasound surgery
    Kuroda, K
    Chung, AH
    Hynynen, K
    Jolesz, FA
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (01): : 175 - 181
  • [6] High-precision mapping of the magnetic field utilizing the harmonic function mean value property
    Li, L
    Leigh, JS
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2001, 148 (02) : 442 - 448
  • [7] LI L, 2000, P 8 ANN M ISMRM DENV, P1773
  • [8] MRI monitoring of interstitial microwave-induced heating and thermal lesions in rabbit brain in vivo
    Moriarty, JA
    Chen, JC
    Purcell, CM
    Ang, LC
    Hinks, RS
    Peters, RD
    Henkelman, RM
    Plewes, DB
    Bronskill, MJ
    Kucharczyk, W
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (01): : 128 - 135
  • [9] SHAPIRO EM, 2000, P 8 ANN M ISMRM DENV, P2001
  • [10] Shapiro EM, 2000, MAGN RESON MATER PHY, V10, P114