Cerebral oximetry for the detection of cerebral ischemia during temporary carotid artery occlusion

被引:28
作者
Takeda, N
Fujita, K
Katayama, S
Tamaki, N
机构
[1] Nishi Kobe Med Ctr, Dept Neurosurg, Nishi Ku, Kobe, Hyogo 6512273, Japan
[2] Kobe Univ, Sch Med, Dept Neurosurg, Kobe, Hyogo 650, Japan
来源
NEUROLOGIA MEDICO-CHIRURGICA | 2000年 / 40卷 / 11期
关键词
cerebral ischemia; near-infrared spectroscopy; cerebral oxygen saturation; carotid endarterectomy;
D O I
10.2176/nmc.40.557
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The near-infrared spectroscopy cerebral oximeter was assessed as a monitoring device for detecting and/or predicting cerebral ischemia during carotid endarterectomy (CEA) and the balloon occlusion test in 24 patients, 12 males and 12 females aged 28 to 77 years (mean 59.9 years). Tolerance testing of complete internal carotid artery (ICA) occlusion by balloon inflation for 20 minutes was performed in nine patients (cerebral aneurysm 6, neck tumor 3) and CEA was performed in 15 patients. The probe of the cerebral oximeter was placed on the forehead of the affected side and regional cerebral oxygen saturation (rSO(2)) was monitored continuously during all procedures. Stump pressure was measured just after ICA occlusion. Collateral circulation detected by digital subtraction angiography was classified into three groups: good, moderate, or poor. Stump pressure was 41-90 mmHg (mean 61.3 mmHg) in the good collateral circulation group, 40-43 mmHg (41.5 mmHg) in the moderate group, and 14-30 mmHg (23.8 mmHg) in the poor group. Change in rSO(2) after ICA occlusion was + 3.5- - 4.2% (mean - 1.6%) in the good collateral circulation group, -1.2- -6.6% (-3.2%) in the moderate group, and -2.4- -10.2% (-6.6%) in the poor group. Changes in rSO(2) were significantly different between the good and poor collateral circulation groups (p < 0.01). A greater than 5% fall in rSO(2) was observed in 0 of 15 patients in the good collateral circulation group, one of five in the moderate group, and three of four in the poor group. The cerebral oximeter is a useful, real-time, non-invasive method to measure brain oxygenation during CEA, skull base surgery, or other procedures which need to evaluate brain ischemia. A fall of greater than 10% from the rSO(2) baseline value is dangerous, but less than 5% is safe.
引用
收藏
页码:557 / 562
页数:6
相关论文
共 13 条
[1]  
ALU L, 1996, ANESTEZIOL REANIMAT, V2, P55
[2]   Cerebral oxygenation measured by near-infrared spectroscopy: Comparison with jugular bulb oximetry [J].
Daubeney, PEF ;
Pilkington, SN ;
Janke, E ;
Charlton, GA ;
Smith, DC ;
Webber, SA .
ANNALS OF THORACIC SURGERY, 1996, 61 (03) :930-934
[3]   USE OF CEREBRAL OXIMETRY TO MONITOR BRAIN OXYGENATION RESERVES FOR SKULL BASE SURGERY [J].
DUJOVNY, M ;
SLAVIN, KV ;
HERNANDEZ, G ;
GEREMIA, GK ;
AUSMAN, JI .
SKULL BASE SURGERY, 1994, 4 (03) :117-121
[4]   CEREBRAL OXIMETRY - A USEFUL MONITOR DURING CAROTID-ARTERY SURGERY [J].
DUNCAN, LA ;
RUCKLEY, CV ;
WILDSMITH, JAW .
ANAESTHESIA, 1995, 50 (12) :1041-1045
[5]   NEAR-INFRARED SPECTROSCOPY IN ADULTS - EFFECTS OF EXTRACRANIAL ISCHEMIA AND INTRACRANIAL HYPOXIA ON ESTIMATION OF CEREBRAL OXYGENATION [J].
GERMON, TJ ;
KANE, NM ;
MANARA, AR ;
NELSON, RJ .
BRITISH JOURNAL OF ANAESTHESIA, 1994, 73 (04) :503-506
[6]  
HERNANDEZAVILA G, 1995, AM J NEURORADIOL, V16, P1618
[7]   NONINVASIVE, INFRARED MONITORING OF CEREBRAL AND MYOCARDIAL OXYGEN SUFFICIENCY AND CIRCULATORY PARAMETERS [J].
JOBSIS, FF .
SCIENCE, 1977, 198 (4323) :1264-1267
[8]   An additional monitoring of regional cerebral oxygen saturation to HMPAO SPECT study during balloon test occlusion [J].
Kaminogo, M ;
Ochi, M ;
Onizuka, M ;
Takahata, H ;
Shibata, S .
STROKE, 1999, 30 (02) :407-413
[9]  
MCCORMICK P W, 1991, Neurological Research, V13, P65
[10]   REGIONAL CEREBROVASCULAR OXYGEN-SATURATION MEASURED BY OPTICAL SPECTROSCOPY IN HUMANS [J].
MCCORMICK, PW ;
STEWART, M ;
GOETTING, MG ;
BALAKRISHNAN, G .
STROKE, 1991, 22 (05) :596-602