PCDD/F- and PAH-emission from house heating systems

被引:29
作者
Launhardt, T
Strehler, A
Dumler-Gradl, R
Thoma, H
Vierle, O
机构
[1] Tech Univ Munich, Bayer Landesanstalt Landtech, D-85354 Freising, Germany
[2] Bayer Landesamt Umweltschutz, D-81901 Munich, Germany
关键词
D O I
10.1016/S0045-6535(98)00265-3
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Combustion experiments were carried out in different house heating systems using various fuels, The emission samples and the chimney soot samples were analyzed for polychlorinated dibenzo-p-dioxins/furans (PCDD/F) and polycyclic-aromatic-hydrocarbons (PAH), The PCDD/F-concentrations in fluegases using untreated wood were in the range of 2-25 pg I-TE/m(3). The combustion of paper, cartons, painted wood and wood with 2-5% PVC gave PCDD/F-concentrations from 38 to 952 pg I-TE/m(3) and 380 to 2 240 ng I-TE/kg (chimney soot). The PAH-concentrations in flue gas were about 30 times higher using an old technology in relation to a new one. (C)1998 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:2013 / 2020
页数:8
相关论文
共 7 条
[1]  
DUMLERGRADL R, 1995, ORGANOHALOGEN COMPOU, V22, P115
[2]  
HAGENMAIER H, 1987, VDI BER, V634, P61
[3]  
LAUNHARDT T, 1997, ABSCHLUSSBERICHT LAN
[4]   PCDD/F-CONCENTRATIONS IN CHIMNEY SOOT FROM HOUSE HEATING-SYSTEMS [J].
THOMA, H .
CHEMOSPHERE, 1988, 17 (07) :1369-1379
[5]  
*VDI, 1993, 3499 VDI, V5
[6]  
*VDI, 1975, 206L VDI
[7]  
*VDI, 1975, 2066 VDI