Electroanalytical applications of cationic self-assembled monolayers, square-wave voltammetric determination of dopamine and ascorbate

被引:207
作者
Raj, CR [1 ]
Tokuda, K [1 ]
Ohsaka, T [1 ]
机构
[1] Tokyo Inst Technol, Interdisciplinary Grad Sch Engn Sci, Dept Elect Chem, Midori Ku, Yokohama, Kanagawa 2268502, Japan
来源
BIOELECTROCHEMISTRY | 2001年 / 53卷 / 02期
关键词
cationic self-assembled monolayer; simultaneous determination; ascorbate; dopamine;
D O I
10.1016/S0302-4598(00)00129-X
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Gold electrodes modified with cationic self-assembled monolayers (SAMs) of 2,2 ' -dithiobisethaneamine (CYST) and 6,6 ' -dithiobishexaneamine (DTH) were used for the simultaneous determination of dopamine (DA) and ascorbate (Ah). The cationic SAM modified electrodes have several advantages over the bare electrode for the oxidation of AA. A very large(similar to 450 mV) decrease in the overpotential for the oxidation of AA when compared with the bare electrode has been observed at the cationic monolayer-modified electrode. The electrostatic interaction of negatively charged AA with the monolayer shift the oxidation peak potential of AA to less positive potential and enhances the peak current. On the other hand, the positively charged DA is repelled from the monolayer and the oxidation potential shifts to more positive potential when compared to the bare electrode. The electrochemical oxidation of AA at the mixed monolayer of CYST and diethyl disulfide (DEDS) supports the influence of cationic terminal group of the monolayer on the oxidation of AA. Since the oxidation of AA occurs well before the oxidation potential of DA is reached, the homogeneous catalytic oxidation of AA by the oxidized DA has been advantageously eliminated at the monolayer-modified electrode. The cationic self-assembled monolayers successfully detect DA in the presence of high concentration of AA. The sensitivity of the electrode modified with CYST monolayer was found to be 0.036 and 0.021 muA/muM towards AA and DA, respectively. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:183 / 191
页数:9
相关论文
共 42 条
[1]  
Adams R. N., 1976, ANAL CHEM, V48, p1128A
[2]  
BOULTON AA, 1995, VOLTAMMETRIC METHODS
[3]   NAFION-COATED CARBON-FIBER ELECTRODES FOR NEUROCHEMICAL STUDIES IN BRAIN-TISSUE [J].
CAPELLA, P ;
GHASEMZADEH, B ;
MITCHELL, K ;
ADAMS, RN .
ELECTROANALYSIS, 1990, 2 (03) :175-182
[4]   Electrocatalysis of ascorbic acid ion the glassy carbon electrode chemically modified with polyaniline films [J].
Casella, IG ;
Guascito, MR .
ELECTROANALYSIS, 1997, 9 (18) :1381-1386
[5]  
Cass A. E. G., 1990, BIOSENSORS PRACTICAL
[6]   Detection of dopamine in the presence of a large excess of ascorbic acid by using the powder microelectrode technique [J].
Chen, J ;
Cha, CS .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 463 (01) :93-99
[7]  
CHENG CA, 1995, ANAL CHEM, V67, P2767
[8]   FREE-ENERGY AND TEMPERATURE-DEPENDENCE OF ELECTRON-TRANSFER AT THE METAL-ELECTROLYTE INTERFACE [J].
CHIDSEY, CED .
SCIENCE, 1991, 251 (4996) :919-922
[9]   Electrochemical behavior of gold electrodes modified with self-assembled monolayers with an acidic end group for selective detection of dopamine [J].
Dalmia, A ;
Liu, CC ;
Savinell, RF .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1997, 430 (1-2) :205-214
[10]   RESPONSE OF MICROVOLTAMMETRIC ELECTRODES TO HOMOGENEOUS CATALYTIC AND SLOW HETEROGENEOUS CHARGE-TRANSFER REACTIONS [J].
DAYTON, MA ;
EWING, AG ;
WIGHTMAN, RM .
ANALYTICAL CHEMISTRY, 1980, 52 (14) :2392-2396