Improvement in glycemic excursions with a transcutaneous, real-time continuous glucose sensor

被引:141
作者
Garg, S
Zisser, H
Schwartz, S
Bailey, T
Kaplan, R
Ellis, S
Jovanovic, L
机构
[1] Univ Colorado, Barbara Davis Ctr Childhood Diabet, Hlth Sci Ctr, Aurora, CO 80010 USA
[2] Sansum Diabet Res Inst, Santa Barbara, CA USA
[3] Diabet & Glandular Dis Res Associates, San Antonio, TX USA
[4] N Cty Endocrine Grp, Escondido, CA USA
[5] E Bay Clin Trial Ctr, Concord, CA USA
关键词
D O I
10.2337/diacare.29.1.44
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE - Hypoglycemia and wide glucose excursions continue to be major obstacles to achieving target HbA(1c) values and the associated reductions in long-term complications (and economic costs) in people with insulin-treated diabetes. In this study we evaluated the accuracy, safety, and clinical effectiveness of a continuous glucose-sensing device. RESEARCH DESIGN AND METHODS - A total of 91 insulin-requiring patients with type 1 (n = 75) and type 2 (n = 16) diabetes were enrolled in this multicenter randomized study. Subjects wore a transcutaneous, 3-day, continuous glucose-sensing system for three consecutive 72-h periods. Subjects were randomly assigned (1:1 ratio) to either a control group (continuous glucose data not provided) or a display group (continuous glucose data not provided during period 1 but displayed during periods 2 and 3). During periods 2 and 3, patients in the display group had real-time access to sensor glucose values, could review glucose trends over the preceding 1, 3, and 9 h, and were provided with high (>= 200 mg/dl) and low (<= 80 mg/dl) alerts and a low (<= 55 mg/dl) alarm. Sensors were inserted by patients, and both groups used (or wore) the system during daily activities. Device accuracy was assessed by comparing continuous glucose values to paired self-monitoring of blood glucose (SMBG) meter readings. Clinical effectiveness was evaluated by analyzing between-group (control vs. display, periods 2 and 3) and within-group (display, period 1 vs. period 3) differences in time spent in high, low, an target (81-140 mg/dl) glucose zones. RESULTS - When prospective, real-time sensor values were compared with SMBG values, 95.4% of 6,767 paired glucose values fell within Clarke error grid A and B zones. Pearson's correlation coefficient was 0.88, and mean and median absolute relative differences were 21.2 and 15.9%, respectively. No systematic bias was detected at any of the prespecified glucose levels (50, 80, 100, 150, and 200 mg/dl). When compared with control subjects, the display group spent 21% less time as hypoglycemic (< 55 mg/dl), 23% less time as hyperglycemic (>= 240 mg/dl), and 26% more time in the target (81-140 mg/dl) glucose range (P < 0.001 for each comparison). Nocturnal (10:00 P.M. to 6:00 A.M.) hypoglycemia, as assessed at two thresholds, was also reduced by 38% (< 55 mg/dl; P < 0.001) and 33% (55-80 mg/dl; P < 0.001) in the display group compared with control subjects. CONCLUSIONS - We conclude that real-time continuous glucose monitoring for periods up to 72 h is accurate and safe in insulin-requiring subjects with type 1 and type 2 diabetes. This study demonstrates that availability of real-time, continuously measured glucose levels can significantly improve glycemic excursions by reducing exposure to hyperglycemia without increasing the risk of hypoglycemia, which may reduce long-term diabetes complications and their associated economic costs.
引用
收藏
页码:44 / 50
页数:7
相关论文
共 13 条
[1]  
[Anonymous], 1995, DIABETES, V44, P968
[2]   EVALUATING CLINICAL ACCURACY OF SYSTEMS FOR SELF-MONITORING OF BLOOD-GLUCOSE [J].
CLARKE, WL ;
COX, D ;
GONDERFREDERICK, LA ;
CARTER, W ;
POHL, SL .
DIABETES CARE, 1987, 10 (05) :622-628
[3]   Hypoglycemia in diabetes [J].
Cryer, PE ;
Davis, SN ;
Shamoon, H .
DIABETES CARE, 2003, 26 (06) :1902-1912
[4]  
Deming W.E., 1964, Statistical Adjustment of Data
[5]   Improved glucose excursions using an implantable real-time continuous glucose sensor in adults with type 1 diabetes [J].
Garg, SK ;
Schwartz, S ;
Edelman, SV .
DIABETES CARE, 2004, 27 (03) :734-738
[6]   Should minimal blood glucose variability become the gold standard of glycemic control? [J].
Hirsch, IB ;
Brownlee, M .
JOURNAL OF DIABETES AND ITS COMPLICATIONS, 2005, 19 (03) :178-181
[7]   Continuous glucose monitoring - Roadmap for 21st century diabetes therapy [J].
Klonoff, DC .
DIABETES CARE, 2005, 28 (05) :1231-1239
[8]   Intensified blood glucose monitoring improves glycemic control in stable, insulin-treated veterans with type 2 diabetes - The Diabetes Outcomes in Veterans Study (DOVES) [J].
Murata, GH ;
Shah, JH ;
Hoffman, RM ;
Wendel, CS ;
Adam, KD ;
Solvas, PA ;
Bokhari, SU ;
Duckworth, WC .
DIABETES CARE, 2003, 26 (06) :1759-1763
[9]  
NATHAN DM, 2005, P 65 ANN SCI SESS AM, P10
[10]  
Nordfeldt S, 2001, ACTA PAEDIATR, V90, P137