Left atrial versus left ventricular input function for quantification of the myocardial blood flow with nitrogen-13 ammonia and positron emission tomography

被引:14
作者
Hove, JD [1 ]
Iida, H
Kofoed, KF
Freiberg, J
Holm, S
Kelbaek, H
机构
[1] Rigshosp, Ctr Heart, Dept Med B, Dept Cardiol, DK-2100 Copenhagen, Denmark
[2] Rigshosp, Neurobiol Res Unit, DK-2100 Copenhagen, Denmark
[3] Rigshosp, PET Ctr, DK-2100 Copenhagen, Denmark
[4] Rigshosp, Dept Nucl Med & Clin Physiol, DK-2100 Copenhagen, Denmark
关键词
PET; nitrogen-13; ammonia; blood flow; input function; spillover;
D O I
10.1007/s00259-003-1329-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Flow quantitation with nitrogen-13 ammonia ((NH3)-N-13) and positron emission tomography (PET) is dependent on an accurate blood time-activity curve. This is conveniently derived from the PET images by drawing a region of interest in the left ventricular cavity. The blood time-activity curve obtained in this way, however, may contain spillover from the myocardial wall. The purpose of this study was to analyse the effect of wall to blood pool spillover. Additionally, we analysed the application of a left atrial input function. Using computer simulations, we investigated the effect of spillover from the myocardial wall to the left ventricular input function and the effect of time delay on the left ventricular input function. An oxygen-15 carbon monoxide PET study of seven normal volunteers was used to investigate possible recovery issues regarding the left atrial input function. Finally, (NH3)-N-13 studies of 31 normal volunteers during rest and dipyridamole stimulation were analysed using either a left atrial or a left ventricular input function. The simulation studies showed that myocardial wall to blood pool spillover causes a considerable underestimation of the regional blood flow values in hyperaemic flow studies. Neither time delay nor recovery issues prevent flow quantitation with a left atrial input function. The (NH3)-N-13 studies revealed no significant difference between the resting blood flow values, whereas the hyperaemic blood flow values were underestimated by 8% (P<0.01) on average (up to 40% individually) when using a left ventricular input function compared with a left atrial input function. Spillover of activity from the left ventricular wall to the blood time-activity curve is of importance in hyperaemic flow studies using (NH3)-N-13. Application of a left atrial input function is a possible solution to these issues.
引用
收藏
页码:71 / 76
页数:6
相关论文
共 18 条
[1]   DIRECT COMPARISON OF [N-13] AMMONIA AND [O-15]WATER ESTIMATES OF PERFUSION WITH QUANTIFICATION OF REGIONAL MYOCARDIAL BLOOD-FLOW BY MICROSPHERES [J].
BOL, A ;
MELIN, JA ;
VANOVERSCHELDE, JL ;
BAUDHUIN, T ;
VOGELAERS, D ;
DEPAUW, M ;
MICHEL, C ;
LUXEN, A ;
LABAR, D ;
COGNEAU, M ;
ROBERT, A ;
HEYNDRICKX, GR ;
WIJNS, W .
CIRCULATION, 1993, 87 (02) :512-525
[2]  
DEGRADO TR, 1994, J NUCL MED, V35, P1398
[3]  
Gambhir S, 1996, P ANN M SOC COMP SIM, P173
[4]  
HERRERO P, 1994, J NUCL MED, V35, P558
[5]   DESIGN AND EVALUATION OF HEADTOME-IV, A WHOLE-BODY POSITRON EMISSION TOMOGRAPH [J].
IIDA, H ;
MIURA, S ;
KANNO, I ;
MURAKAMI, M ;
TAKAHASHI, K ;
UEMURA, K ;
HIROSE, Y ;
AMANO, M ;
YAMAMOTO, S ;
TANAKA, K .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) :1006-1010
[6]   Glucose metabolism in reperfused myocardium measured by [2-18F] 2-fluorodeoxyglucose and PET [J].
Kofoed, KF ;
Schöder, H ;
Knight, RJ ;
Buxton, DB .
CARDIOVASCULAR RESEARCH, 2000, 45 (02) :321-329
[7]   Relationship between regional 18F-fluorodeoxyglucose and 13N ammonia uptake in normal myocardium assessed by positron emission tomography:: Patterns of mismatch and effects of aging [J].
Kofoed, KF ;
Hove, JD ;
Freiberg, J ;
Host, U ;
Hesse, B ;
Kelbæk, H .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2001, 17 (05) :361-370
[8]   N-13 AMMONIA MYOCARDIAL IMAGING AT REST AND WITH EXERCISE IN NORMAL VOLUNTEERS - QUANTIFICATION OF ABSOLUTE MYOCARDIAL PERFUSION WITH DYNAMIC POSITRON EMISSION TOMOGRAPHY [J].
KRIVOKAPICH, J ;
SMITH, GT ;
HUANG, SC ;
HOFFMAN, EJ ;
RATIB, O ;
PHELPS, ME ;
SCHELBERT, HR .
CIRCULATION, 1989, 80 (05) :1328-1337
[9]   QUANTIFICATION OF REGIONAL MYOCARDIAL BLOOD-FLOW USING N-13 AMMONIA AND REORIENTED DYNAMIC POSITRON EMISSION TOMOGRAPHIC IMAGING [J].
KUHLE, WG ;
PORENTA, G ;
HUANG, SC ;
BUXTON, D ;
GAMBHIR, SS ;
HANSEN, H ;
PHELPS, ME ;
SCHELBERT, HR .
CIRCULATION, 1992, 86 (03) :1004-1017
[10]  
MARTIN W, 1987, J CEREB BLOOD FLOW M, V7, P1421