Ultrasonographic guidance improves the success rate of interscalene brachial plexus blockade

被引:189
作者
Kapral, Stephan [1 ]
Greher, Manfred [3 ]
Huber, Gudrun [1 ]
Willschke, Harald
Kettner, Stephan [1 ]
Kdolsky, Richard [2 ]
Marhofer, Peter [1 ]
机构
[1] Med Univ Vienna, Dept Anaesthesia Gen Intens Care Med, Vienna, Austria
[2] Med Univ Vienna, Dept Trauma Surg, Vienna, Austria
[3] Herz Jesu Hosp, Dept Anaesthesia & Perioperat Intens Care & Pain, Vienna, Austria
关键词
regional anesthetic technique; interscalene brachial plexus block; equipment : ultrasound; local anesthetics : ropivacaine;
D O I
10.1016/j.rapm.2007.10.011
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background and Objectives: The use of ultrasonography in regional anesthetic blocks has rapidly evolved over the past few years. it has been speculated that ultrasound guidance might increase success rates and reduce complications. The aim of our study is to compare the success rate and quality of interscalene brachial plexus blocks performed either with direct ultrasound visualization or with the aid of nerve stimulation to guide needle placement. Methods: A total of 160 patients (American Society of Anesthesiologists physical status classification I-III) scheduled for trauma-related upper arm surgery were included in this randomized study and grouped according to the guidance method used to deliver 20 mL of ropivacaine 0.75% for interscalene brachial plexus blockade. in the ultrasound group (n = 80), the brachial plexus was visualized with a linear 5 to 10 MHz probe and the spread of the local anesthetic was assessed. In the nerve stimulation group (n = 80), the roots of the brachial plexus were located using a nerve stimulator (0.5 mA, 2 Hz, and 0.1 millisecond bandwidth). The postblock neurologic assessment was performed by a blinded investigator. Results: Sensory and motor blockade parameters were recorded at different points of time. Surgical anesthesia was achieved in 99% of patients in the ultrasound vs 91% of patients in the nerve stimulation group (P <.01). Sensory, motor, and extent of blockade was significantly better in the ultrasound group when compared with the nerve stimulation group. Conclusions: The use of ultrasound to guide needle placement and monitor the spread of local anesthetic improves the success rate of interscalene brachial plexus block.
引用
收藏
页码:253 / 258
页数:6
相关论文
共 22 条
[1]   Ultrasound-guided interscalene block for shoulder dislocation reduction in the ED [J].
Blaivas, M ;
Lyon, M .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2006, 24 (03) :293-296
[2]   Ultrasound guidance improves success rate of axillary brachial plexus block [J].
Chan, Vincent W. S. ;
Perlas, Anahi ;
McCartney, Colin J. L. ;
Brull, Richard ;
Xu, Daquan ;
Abbas, Sherif .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2007, 54 (03) :176-182
[3]   Applying ultrasound Imaging to interscalene brachial plexus block [J].
Chan, VWS .
REGIONAL ANESTHESIA AND PAIN MEDICINE, 2003, 28 (04) :340-343
[4]  
CONN RA, 1987, CLIN ORTHOP RELAT R, P94
[5]  
DEJONG RH, 1977, LOCAL ANESTHETICS, P197
[6]   Ultrasound guidance as a gold standard in regional anaesthesia [J].
Hopkins, P. M. .
BRITISH JOURNAL OF ANAESTHESIA, 2007, 98 (03) :299-301
[7]  
Jandrasits O, 1998, ACTA ANAESTH SCAND, V42, P48
[8]  
KANDALL FP, 1988, GRUNDLAGEN MANUELLEN
[9]  
KAPRAL S, 1995, REGION ANESTH, V20, P323
[10]  
KAPRAL S, 1994, ANESTH ANALG, V78, P507