Current trends in explosive detection techniques

被引:429
作者
Caygill, J. Sarah [1 ]
Davis, Frank [1 ]
Higson, Seamus P. J. [1 ]
机构
[1] Cranfield Univ, Cranfield MK43 0AL, Beds, England
基金
英国工程与自然科学研究理事会;
关键词
Explosives detection; Explosive-related compound; Counter-terrorism; Review; INDUCED BREAKDOWN SPECTROSCOPY; DESORPTION ELECTROSPRAY-IONIZATION; PLASMON RESONANCE IMMUNOSENSOR; MOLECULARLY IMPRINTED POLYMERS; ION MOBILITY SPECTROMETRY; ELECTROCHEMICAL DETECTION; MASS-SPECTROMETRY; TRACE DETECTION; NITROAROMATIC EXPLOSIVES; TERAHERTZ SPECTROSCOPY;
D O I
10.1016/j.talanta.2011.11.043
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学];
摘要
The detection of explosives and explosive-related compounds has become a heightened priority in recent years for homeland security and counter-terrorism applications. There has been a huge increase in research within this area-through both the development of new, innovative detection approaches and the improvement of existing techniques. Developments for miniaturisation, portability, field-ruggedisation and improvements in stand-off distances, selectivity and sensitivity have been necessary to develop and improve techniques. This review provides a consolidation of information relating to recent advances in explosive detection techniques without being limited to one specific research area or explosive type. The focus of this review will be towards advances in the last 5 years, with the reader being referred to earlier reviews where appropriate. (C) 2011 Published by Elsevier B.V.
引用
收藏
页码:14 / 29
页数:16
相关论文
共 146 条
[1]
Rapid voltammetric determination of nitroaromatic explosives at electrochemically activated carbon-fibre electrodes [J].
Agüí, L ;
Vega-Montenegro, D ;
Yáñez-Sedeño, P ;
Pingarrón, JM .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (02) :381-387
[2]
A Hybrid Nanosensor for TNT Vapor Detection [J].
Aguilar, Alvaro Diaz ;
Forzani, Erica S. ;
Leright, Mathew ;
Tsow, Francis ;
Cagan, Avi ;
Iglesias, Rodrigo A. ;
Nagahara, Larry A. ;
Amlani, Islamshah ;
Tsui, Raymond ;
Tao, N. J. .
NANO LETTERS, 2010, 10 (02) :380-384
[3]
Ambient mass spectrometry: bringing MS into the "real world" [J].
Alberici, Rosana M. ;
Simas, Rosineide C. ;
Sanvido, Gustavo B. ;
Romao, Wanderson ;
Lalli, Priscila M. ;
Benassi, Mario ;
Cunha, Ildenize B. S. ;
Eberlin, Marcos N. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 398 (01) :265-294
[4]
CdSe quantum dots capped PAMAM dendrimer nanocomposites for sensing nitroaromatic compounds [J].
Algarra, M. ;
Campos, B. B. ;
Miranda, M. S. ;
Esteves da Silva, Joaquim C. G. .
TALANTA, 2011, 83 (05) :1335-1340
[5]
Raman spectroscopy and security applications: the detection of explosives and precursors on clothing [J].
Ali, Esam M. A. ;
Edwards, Howell G. M. ;
Scowen, Ian J. .
JOURNAL OF RAMAN SPECTROSCOPY, 2009, 40 (12) :2009-2014
[6]
In-situ detection of single particles of explosive on clothing with confocal Raman microscopy [J].
Ali, Esam M. A. ;
Edwards, Howell G. M. ;
Scowen, Ian J. .
TALANTA, 2009, 78 (03) :1201-1203
[7]
Detection of explosives on human nail using confocal Raman microscopy [J].
Ali, Esarn M. A. ;
Edwards, Howell G. M. ;
Hargreaves, Michael D. ;
Scowen, Ian J. .
JOURNAL OF RAMAN SPECTROSCOPY, 2009, 40 (02) :144-149
[8]
BEAD-BASED FLUID ARRAY DETECTION OF PENTAERYTHRITOL TETRANITRATE: COMPARISON OF MONOCLONAL VS. LLAMA POLYCLONAL ANTIBODIES [J].
Anderson, George P. ;
Moore, Martin ;
Charles, Paul T. ;
Goldman, Ellen R. .
ANALYTICAL LETTERS, 2010, 43 (18) :2913-2922
[9]
TNT detection using multiplexed liquid array displacement immunoassays [J].
Anderson, GP ;
Moreira, SC ;
Charles, PT ;
Medintz, IL ;
Goldman, ER ;
Zeinali, M ;
Taitt, CR .
ANALYTICAL CHEMISTRY, 2006, 78 (07) :2279-2285
[10]
Performance evaluation of a miniature ion mobility spectrometer drift cell for application in hand-held explosives detection ion mobility spectrometers [J].
Babis, J. S. ;
Sperline, R. P. ;
Knight, A. K. ;
Jones, D. A. ;
Gresham, C. A. ;
Denton, M. B. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 395 (02) :411-419