Frequency response characteristics of an active heat flux gage

被引:5
作者
Dinu, C [1 ]
Beasley, DE [1 ]
Figliola, RS [1 ]
机构
[1] Sch Mech & Ind Engn, Thermal Fluid Sci Res Lab, Clemson, SC 29634 USA
来源
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME | 1998年 / 120卷 / 03期
关键词
analog techniques; instrumentation; measurement techniques;
D O I
10.1115/1.2824314
中图分类号
O414.1 [热力学];
学科分类号
摘要
The transient response and frequency response of a constant-temperature platinum film gage are computationally modeled for application to heat flux measurement. The probe consists of a thin platinum film (sensor) deposited on a Pyrex substrate, and coated with aluminum oxide. The probe is exposed to a convective environment, and the power required to maintain the sensor at a constant temperature is,a direct indication of the local, instantaneous heat transfer rate. In application, the probe is mounted in a heated, high thermal conductivity material, creating an isothermal heat transfer surface. A two-dimensional numerical model was developed to represent the sensor, the Pyrex substrate and the coating. Ideally, the probe would be operated with the platinum at identically the same temperature as the isothermal surface. In the present study, the effects of non-ideal operating conditions, resulting in differences between the sensor and surface temperature, are examined. Frequency response characteristics are presented in a nondimensional form. The results of this modeling effort clearly indicate the importance of precise control over the sensor temperature in employing the present method for heat flux measurement. With the sensor temperature equal to the isothermal surface temperature, the probe calibration is insensitive to the heat transfer rate over a wide range of heat transfer coefficients. However, a 0.5 degrees C difference between the sensor and surface temperatures yields a change in the calibration of approximately 20 percent over a range of heat transfer coefficient of 500 W/m(2)K. At an input frequency of 10 Hz and an average heat transfer coefficient of 175 W/m(2)K, amplitude errors increase from 3 percent to 35 percent as the temperature difference changes from zero to 1 degrees C. These results are useful guide to calibration, operation, and data reduction in active heat flux measurement.
引用
收藏
页码:577 / 582
页数:6
相关论文
共 7 条
[1]   A GENERALIZED ANALYSIS OF A LOCAL HEAT-FLUX PROBE [J].
BEASLEY, DE ;
FIGLIOLA, RS .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1988, 21 (03) :316-322
[2]  
Diller T. E., 1993, ADV HEAT TRANSFER, V23, P279, DOI DOI 10.1016/S0065-2717(08)70008-X
[3]   Boundary condition influences on the effective area of a local heat flux probe [J].
Figliola, RS ;
Swaminathan, M .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1996, 7 (10) :1439-1443
[4]   A STUDY OF THE DYNAMIC-RESPONSE OF A LOCAL HEAT-FLUX PROBE [J].
FIGLIOLA, RS ;
SWAMINATHAN, M ;
BEASLEY, DE .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1993, 4 (10) :1052-1057
[5]   TRANSIENT CONJUGATED HEAT-TRANSFER FROM A RECTANGULAR HOT FILM [J].
LIANG, PW ;
COLE, KD .
JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 1992, 6 (02) :349-355
[6]   UNSTEADY HEAT-TRANSFER FROM A THICK HOT-FILM SENSOR [J].
PARK, CH ;
COLE, KD .
JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 1994, 8 (04) :797-799
[7]  
PARK CH, 1996, P 1996 IMECE ATL GA